Mobile Installation; Fixed Station Installation - RCA BRM300DV Instruction Manual

Vhf/uhf
Table of Contents

Advertisement

10
Figure 4
Fuse holders
then attach the power cable to the battery
terminals; red connects to the positive (+)
terminal and black connects to the negative
(-) terminal. Use the full length of the supplied
cable without cutting off excess even If the
cable is longer than required. In particular,
never remove the fuse holders from the cable.
(Figure 4)
5. Reconnect any wiring removed from the
Supplied
cable
Fuse
holder
BRM300D
Professional Digital Two-Way Mobile Radio Instruction Manual
TM
Figure 5
Copyright © 2015 RCA Communications Systems
negative terminal.
6. Connect the DC power cable to the transceiver's
power supply connector. Press the connectors
firmly together until the locking tab connectors
firmly together until the locking tab clicks.
(Figure 5)
Fixed Station Operation
In order to use this transceiver in a fixed station
operation, you will need a separate 13.8V DC
power supply (not included). The recommended
current capacity of your power supply is 14A or
more.
1. Connect the DC power cable to the regulated
DC power supply and ensure that the polarities
are correct (Red: positive, Black: negative).
• Do not directly connect the transceiver to
an AC outlet.
• Use the supplied DC power cable to
connect the transceiver to a regulated
power supply. Do not substitute a cable
with smaller gauge wires. (Figure 6)