Elation PLATINUM 1200 WASH User Manual page 32

Table of Contents

Advertisement

ELATION© PLATINUM 1200 WASH™
E R R O R
C O D E S
Error Codes are subject to change without any prior written notice.
ERROR CODE
DESCRIPTION
The PAN movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
PAN
(sensor failed or magnet is missing) or there is a motor failure (defective motor or a
defective motor IC drive on the main PCB). This error may also be displayed if the
head/yoke was blocked during a reset function.
The TILT movement is not located in the default position after the reset.
This message will appear after a fixture reset if the magnetic-indexing circuit malfunctions
TILT
(sensor failed or magnet is missing) or there is a motor failure (defective motor or defective
motor IC drive on main PCB). This error may also be displayed if the head was blocked
during a reset function.
The Zoom movement is not located in the default position after the reset.
This message will appear after the reset of the fixture reset if the magnetic-indexing circuit
ZOOM
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or defective motor IC drive on main PCB).
www.elationlighting.com