Certification And Conformity Details; Table 9 Standards Australia (Losc) Certification; Table 10 Zone 2 (Europe) Declaration Of Conformity - Honeywell RMA 3000 User Manual

Remote meter assemblies
Hide thumbs Also See for RMA 3000:
Table of Contents

Advertisement

Certification and
Conformity Details
(continued)
42

Table 9 Standards Australia (LOSC) Certification

Code
4H
Intrinsically Safe Ex ia IIC T4 Class I Zone 0.
Flameproof Ex d IIC T6 Class I Zone 1
Non-Sparking Apparatus - Type of Protection 'n' Ex n IIC T6 Class I
Zone 2
LOSC Intrinsic Safety Parameters (1)
Ui =
Ii =
Pi =
Ci =
Li =
Li =
(1)
Install in accordance with Honeywell drawing 51204309.

Table 10 Zone 2 (Europe) Declaration of Conformity

Code
3N
Electrical Apparatus With Type of Protection "n" per IEC 79-
15. IP 66/67.
Ex II 3 GD T
Temp. Code
Temp. Code
Temp. Code
34-ST-25-19 RMA 3000 Remote Meter Assemblies User Manual
Description
42.4 V
225 mA
1.2 W
4.2 nF
0
With no integral indicator, or with integral
Smart Meter, option SM.
150 µH
With Analog Meter, option ME.
Description
(1)
X (Council Directive 94/9/EC) −40 ≤ Ta ≤ 93°C.
Zone 2 Parameters
≤ 42 V
U
i
≤ 22 mA
I
i
(1)
T4 at Ta 93°C Maximum Ambient
(1)
T5 at Ta 80°C Maximum Ambient
(1)
T6 at Ta 65°C Maximum Ambient
Release: 1
6/04

Hide quick links:

Advertisement

Table of Contents
loading