Download Print this page

Nagano Keiki KH41 Manual page 7

Process applications pressure transmitter

Advertisement

Model number configuration 3
Model
K D 4 1
Process Applications
Pressure Transmitters
Model number
Type
Connection
Please specify applicable
range code as well as
pressure range and
engineering unit.
「Manufacturing range」
  ・ Power source 12 to 32V DC
・ Adjustable cable diameter φ7 to φ12
Treatment of wetted parts
■Use no oil
 Manufacture/process wetted parts not to retain oils.
■Use no water
 Manufacture/process wetted parts not to retain water.
■Use no oil & water
 Manufacture/process wetted parts not to retain oils and water.
*Specify by code "X" if there is no applicable specification.
KH41 ・43, KD41 ・43
Process Applications Pressure Transmitter
Please specify the model number, each specs and the range for ordering.
3
4
Direct mounting
5
Surface mounting
6
2B Pipe mounting
7
Direct mounting
8
Surface mounting
9
2B Pipe mounting
3
G3/8B (Diaphragm only)
9
Rc1/2
3
SCS14 + SUS316 + SUS304 
Wetted parts
material
Pressure range
Accuracy
Power source
1
Selective spec.
Proofpressure gasket tyoe: PF1/2
Proofpressure gasket tyoe: PF1/2
Proofpressure gasket tyoe: PF1/2
Conduit type: G1/2
Conduit type: G1/2
Conduit type: G1/2
1
0 to 5, 10, 20, 30, 40, 50kPa
2
0 to 0.1, 0.2, -0.1 to 0MPa
3
±5, ±10, ±20, ±30, ±40, ±50kPa Compound
4
-0.1 to 0.1, 0.2MPa Compound
4
±0.25%F.S.
5
±0.5%F.S.
1
24V DC±10%
9
Others
1
4 to 20mA DC, 2 wire system
Output
Treatment
Other additional
spec.
Document
7
Additional spec. (Option)
0
Nil
1
Use no oil
2
Use no water
3
Use no oil & water
0
Nil
1
Diaphragm type specification
(Main body + add to the diaphragm part)
(Please refer to SC□□)
0
Nil
1
Required
(Please specify the desired documents separately)
Submission drawings,
instruction manual,
inspection procedure, mill sheet,
test report (1 pc 1 copy),
inspection / traceability certificate,
standard inspection report,
strength calculation,
attended inspection

Advertisement

loading

This manual is also suitable for:

Kd41Kd43Kh43