Download Print this page

Explosion-Proof - Nagano Keiki KH41 Manual

Process applications pressure transmitter

Advertisement

Wiring
Load resistance range
Load resistance (Ω)

Explosion-proof

Explosion-proof type approval:
  Conforms to Ministry of Health, Labour and Welfare
Notification structural standard and new engineering
standard and new explosion-proof policy adjusted by IEC
international standard.
Model
KD41
-0.1 to 0.3→0 to 3.5MPa
KD43
0 to 5→0 to 20MPa
  KD41, 43 Explosion-proof construction d2G4
KD41, 43 Puressure transmitter
Application range: d2G4 
 Explosion-proof construction: d
 Explosion class: 2 (Minimum gap which permits flame
propagation at a gap depth of 25mm is
0.4mm to 0.6mm)
 Ignitability: G4 (Container with an ignition point of 135 to
200° C and whose outside surface temperature
rise limit is 70degs)
 Hazardous areas: Zone 1 or Zone 2
 Objective industries: Petrochemical, chemical fiber,
ethylene, ethanol, methanol, dielectric
 products manufacturing, liquefied gas,
electric furnace, pharmaceuticals,
paints, ammonium sulfate, soda, other
measurement medium or industries in
which there is the danger of explosion.
KH41 ・43, KD41 ・43
Process Applications Pressure Transmitter
K□41
K□43
Receiver
(Example: GC95 Digital meter relay, etc.)
1000
800
600
400
200
Load resistance tolerance
0
0
10 12
Type approval number
No. T54934
No. T54935
No. T55046
Power source 12-32V DC
20 24
32
Voltage (V)
Explosion-proof construction:  
Explosion-proof construction is a totally-enclosed
construction such that even if an explosive gas explodes
inside the container, the container will withstand the force
of the explosion and there is no danger of ignition by
external explosive gases. Our pressure and differential
pressure transmitter manufactured under this policy are
used in pressure measurements where inflammable gas or
the inflammable gas vapors may exist in factories and
business offices.
Classification of hazardous area:
Hazardous area
Areas where a hazardous atmosphere is
Zone 0
continuously present or present for a long
period under ordinary circumstances
Areas where hazardous atmosphere is
Zone 1
likely to occur under ordinary
circumstances
Areas where hazardous atmosphere is
Zone 2
likely to occur under abnormal
circumstances
2
Contents

Advertisement

loading

This manual is also suitable for:

Kd41Kd43Kh43