Measuring
Item
instrument
Ad justment
Signal
of SUB
gener ator
COLOUR Ⅱ Ⅱ Ⅱ Ⅱ
Oscilloscope
Remote
control unit
W
Ye
75%
0%
Cy
G
Fig. 1
W
Ye
Cy G
75%
0%
Fig. 2
Test point
Ad justment part
TP-R
6.COLOUR
TP-E( # # # # )
[CRT
SOCKET
PWB ]
(+)
A
(W- R)
Mg
R
(-)
B
( + )
B
(W- R)
R
Mg
B
(-)
[Method of adjustm ent using measur ing instrument]
< PAL COLOUR >
1. Receive a PAL full field colour bar signal (75% white).
2. Select 2.V/C from the SERVICE MENU.
3. Select 6.COLOUR with the FUNCTION ▲/▼ key.
4. Set the initial setting value of PAL COLOUR with the
FUNCTION
/
5. Connect the osc illosc ope between TP-R and TP-E
6. Adjust PAL COLOUR and bring the value of (A) in the to
illustration (Fig.1) to -140mV(W-R).
7. Press the MENU (OK) key and memorize the setting value.
< SECAM COLOUR >
1. Receive a SECAM full field c olour bar signal (75% white).
2. Set the initial setting value of SECAM COLOUR with the
FUNCTION
/
3. Adjust SECAM COLOUR and bring the value of (A) in the
illustration (Fig.2) to -140mV(W-R).
4. Press the MENU (OK) key and memorize the setting value.
< NT SC 3.58 COLOUR >
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal (full field
colour bar with 75% white) from the EXT terminal.
2. Set the initial s etting value of NTSC 3.58 COLOUR with the
FUNCTION
/
3. Adjust NTSC 3.58 COLOUR and bring the value of (B) of the
illustration (Fig.1) to -140mV(W -B).
4. Press the MENU (OK) key and memorize the setting value.
< NT SC 4.43 COLOUR >
1. When NTSC3.58 adjustment has done, then
adjustment will be automatically s et at the respec tive values.