SPECIFICATIONS
● Measurement functions
Accumulated elapsed time measurement and split time measurement are available.
● Standard measurement
Button A
START
● A ccumulated elapsed time measurement
Button A
START
Restart and stop of the stopwatch can be repeated by pressing button A.
● Split (intermediate) time measurement
Button A
START
Measurement and release of the split time can be repeated by pressing button B.
● Measurement of two competitors
Button A
START
NECESSARY PROCEDURE AFTER BATTERY CHANGE
After installing the battery, pull out the crown to the second click position. And then follow the
instructions below to correct the hand positions and set the time.
Crown
Crown
Button A
Button A
Crown
Button A
Button B
STOP
RESET
Button A
Button A
STOP
RESTART
Button B
SPLIT
SPLIT RELEASE
Button B
FINISH TIME OF FIRST
RUNNER
Pull out to the second click position when the small second hand is at
the 60 seconds position. The small second hand stops on the spot.
Turn to set the main time. * Check that AM/PM is correctly set.
Press Button A for longer than 2 seconds.
The STOPWATCH minute hand turns a full circle.
Press Button B to set the STOPWATCH minute hand to the
Button B
"0" position. It moves quickly if button B is kept pressed.
Press Button A for longer than 2 seconds.
The STOPWATCH hour and second hand turns a full circle.
Press Button B repeatedly to reset the STOPWATCH
Button B
second hand to the "0" position (12:00). It moves quickly
if button B is kept pressed.
Push back in to the normal position in accordance with a time signal.
Button A
... →
STOP
Button B
Button A
STOP
Button A
SECOND RUNNER
FINISH TIME OF
FINISH
SECOND RUNNER
/2
Button B
RESET
Button B
RESET
Button B
Button B
RESET
Cal. 7T04A