INSTALLATION

Safety Precautions

WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be danger-
ous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove
fumes from breathing zone.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or
explosion.
• Keep flammable material away.
• Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body
protection.
------------------------------------------------------------
See additional warning information at
front of this operator's manual.
-----------------------------------------------------------
CORRECT OPERATIONAL USE
The machine should be located in a clean, dry place
where there is free circulation of clean air such that air
movement in through the front and out through the
back will not be restricted. Dirt and dust that can be
drawn into the machine should be kept to a minimum.
Failure to observe these precautions can result in
excessive operating temperatures and nuisance shut-
down of the machine.
Input Rating
Amperes
Voltage
Hertz
Nameplate
230
60
460
575
*
Ambient temperature of 40°C (104°F).
**
At rated output of 400A, 100% duty cycle.
***
Use only Bussmann Super-Lag or Limitron fuses specified. Other fuses may not protect the welder and
may cause overheating and possible fire damage.
INSTALLATION DATA
Recommended input wire and fuse sizes for maximum rated output.
In addition, follow latest National Electrical Code and Local Code.
*
Input Wire Size
**
(Type 75°C Copper
on
Conductors in
Conduit)AWG
77
3 (27mm
)
2
39
8 (8.4mm
)
2
31
10 (5.3mm
)
2
APPLICATION LIMITATIONS
There are no provisions on the CV-400 for paralleling,
and outdoor operations without rain sheltering is not
recommended.
LIMIT ON STACKING
FALLING EQUIPMENT
injury.
• Do not lift this machine using lift bale if
it is equipped with a heavy accessory
such as trailer or gas cylinder.
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
• Do not stack more than three high.
• Do not stack the CV-400 on top of any other
machine.
---------------------------------------------------------------------
The units may be stacked three high by observing the
following safety precautions.
1. Make sure the first or bottom unit is setting on a
level, well supported surface.
2. The units must be stacked with their fronts flush,
making sure the two holes in the base rails of the
unit being stacked on top are over the two holes
located on the top front corners of the unit it is
being stacked on. Fasten the units together with
5/16 bolts, nuts and lockwashers through these
holes.
3. Remove fastening bolts before lifting unit off stacks.
Input Power Connections
By removing the rear access panel the three phase
input power is connected to the three line terminals on
the input contactor, and the earth grounding lead to
the grounding terminal on the input box floor marked
with the
symbol. Install the reconnect panel jumper
links for the proper input voltage per the diagram pasted
inside the access panel cover.
See Installation Data below:
Minimum Grounding
Wire Size
FUSE SIZE AND
(Copper Conductors)
CATALOG NUMBER
AWG
FUSE SIZE BUSSMANN LIMITRON
8 (10mm
)
100
2
10 (5.3mm
)
50
2
10 (5.3mm
)
40
2
16
WARNING
can cause
***
SUPER-LAG
Discont
KTn-R-100
RES-50
KTn-R-50
RES-40
KTn-R-50