Impedance Functions, Alternatives - ABB RED670 Product Manual

Line differential protection red670 2.1 iec
Hide thumbs Also See for RED670:
Table of Contents

Advertisement

Line differential protection RED670 2.1 IEC
Product version: 2.1
Table 184. Impedance functions, alternatives
Function
Note: One, and only one alternative can be selected. Selected qty is 0 for other functions in an unselected alternative.
Alternative 1 Distance protection, quadrilateral
Distance protection zone, quadrilateral characteristic
Directional impedance quadrilateral
Phase selection, quadrilateral characteristic with fixed angle
Alternative 2 Distance protection for series compensated lines, quadrilateral
Phase selection, quadrilateral characteristic with fixed angle
Distance measuring zone, quadrilateral characteristic for series
compensated lines
Directional impedance quadrilateral, including series compensation
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Fullscheme distance protection, mho characteristic
Fullscheme distance protection, quadrilateral for earth faults
Directional impedance element for mho characteristic
Additional distance protection directional function for earth faults
Mho Impedance supervision logic
Faulty phase identification with load encroachment
Alternative 4 Distance protection, quadrilateral with separate settings for PP and PE
Directional impedance quadrilateral
Distance protection zone, quadrilateral characteristic, separate settings
Phase selection, quadrilateral characteristic with settable angle
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series compensated lines, quad and
mho characteristic
Optional for alternative 1
Directional impedance element for mho characteristic
Optional for alternative 3
Phase selection, quadrilateral characteristic with fixed angle
Optional for alternatives 1, 2 and 4
Additional distance protection directional function for earth faults
Faulty phase identification with load encroachment
Optional with any alternative
Power swing detection
Automatic switch onto fault logic, voltage and current based
Power swing logic
PoleSlip/Out-of-step protection
Out-of-step protection
Phase preference logic
Table 185. Current protection
Pos
1
2
3
4
itio
n
C
00
118
5
6
7
8
9
Function
Ordering no
identification
ZMQPDIS,
1MRK005907-AA
ZMQAPDIS
ZDRDIR
1MRK005907-BA
FDPSPDIS
1MRK005907-CA
FDPSPDIS
1MRK005907-CA
ZMCPDIS,
1MRK005907-DA
ZMCAPDIS
ZDSRDIR
1MRK005907-EA
ZMHPDIS
1MRK005907-FA
ZMMPDIS,
1MRK005907-GA
ZMMAPDIS
ZDMRDIR
1MRK005907-HA
ZDARDIR
1MRK005907-KA
ZSMGAPC
1MRK005907-LA
FMPSPDIS
1MRK005907-MA
ZDRDIR
1MRK005907-BA
ZMRPDIS,
1MRK005907-NA
ZMRAPDIS
FRPSPDIS
1MRK005907-PA
ZMFPDIS
1MRK005907-SB
ZMFCPDIS
1MRK005907-RB
ZDMRDIR
1MRK005907-HA
FDPSPDIS
1MRK005907-CA
ZDARDIR
1MRK005907-KA
FMPSPDIS
1MRK005907-MA
ZMRPSB
1MRK005907-UA
ZCVPSOF
1MRK005908-AA
PSLPSCH
1MRK005907-VA
PSPPPAM
1MRK005908-CB
OOSPPAM
1MRK005908-GA
PPLPHIZ
1MRK005908-DA
10
11
12
13
14
0
00
1MRK 505 346-BEN -
Positi
Available
on
qty
1
0-5
2
0-2
3
0-2
3
0-2
4
0-5
5
0-2
6
0-5
7
0-5
8
0-2
9
0-2
10
0-1
11
0-2
2
0-2
12
0-5
13
0-2
14
0-1
15
0-1
8
0-2
3
0-2
9
0-2
11
0-2
16
0-1
17
0-1
18
0-1
19
0-1
20
0-1
22
0-1
15
16
17
18
19
1
0
0
Selected
Notes and
qty
rules
20
21
22
23
0
0
0
ABB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Relion rel670 2.1 iec

Table of Contents