Speed And Defrost Settings - Broan ERV140TE Installation Manual

Hide thumbs Also See for ERV140TE:
Table of Contents

Advertisement

Available languages

Available languages

4. CONTROLS (
CONT
4.3 S
D
PEED AND
EFROST
The special design of these units offers 4 speed ranges to better meet to different ventilation needs.
Refer to the table below to choose the right speed range according to the size of the house:
NOTE: These CFM values are
approximate, they may vary
according to the installation
static pressure.
These units are factory set to normal defrost. In cold region (outside
temperature -17°F [-27°C] and lower), it may be necessary to setup
extended defrost.
T
O MODIFY THE FACTORY SETTINGS
NOTE: Anytime in setting process, if there is no activation on push button for 60 seconds, the unit will automatically exit setting mode, but
the settings made before this 60-second delay will remain.
ACTION
 During the first 7 seconds of booting sequence, while the
integrated control LED is AMBER, press on push button for about
3 seconds.
 Set the speed range by presssing consecutively on push button
the number of times corresponding to the desired speed range.
See table below.
NOTE: It is possible to change the selection as many
times needed.
 Press on push button for about 3 seconds to access setting
defrost mode.
 Press on push button twice to set the unit in extended defrost
mode.
NOTE: It is possible to change the selection as many
times needed.
 Wait 60 seconds OR press 3 seconds on push button to exit
setting mode.
'
)
D
S
ETTINGS
S
R
PEED
ANGE
1
(
HIGH
FACTORY SET
2
-
MED
HIGH
3
-
MED
LOW
4
LOW
,
PROCEED AS FOLLOW
HRV M
. S
HRV M
IN
PEED
)
80 CFM
66 CFM
53 CFM
40 CFM
1 F
2
3 F
4
:
RESULT
 The LED will blink RED one time every 3 seconds to indicate the
integrated control is in CFM setup mode (HIGH speed).
 Every 3 seconds, the LED will blink RED the number of times
corresponding to the chosen speed range.
See table below.
S
R
PEED
ANGE
1
HIGH
2
-
MED
HIGH
3
-
MED
LOW
4
LOW
 The LED will blink GREEN one time every 3 seconds to indicate
the unit is set in normal defrost mode.
 The LED will blink GREEN twice every 3 seconds to indicate the
unit is in extended defrost mode.
D
EFROST TABLE
1
(HRV150TE)
NORMAL
2
(HRV150TE)
EXTENDED
3
(ERV140TE)
NORMAL
4
(ERV140TE)
EXTENDED
 The LED will blink and shut off, then light RED (the unit returns
in its booting sequence).
13
CFM
VALUES
. S
ERV M
. S
AX
PEED
IN
157 CFM
84 CFM
132 CFM
67 CFM
106 CFM
53 CFM
80 CFM
40 CFM
D
EFROST TABLE
S
(HRV150TE)
ACTORY
ET
S
(ERV140TE)
ACTORY
ET
P
RESS ON PUSH BUTTON
O
NCE
T
WICE
T
HREE TIMES
F
OUR TIMES
P
RESS ON PUSH BUTTON
O
NCE
T
WICE
T
H REE TIMES
F
O UR TIMES
ERV M
. S
PEED
AX
PEED
140 CFM
120 CFM
105 CFM
80 CFM
D
EFROST CYCLE
N
(HRV150TE)
ORMAL
E
(HRV150TE)
XTENDED
N
(ERV140TE)
ORMAL
E
(ERV140TE)
XTENDED
LED
RED
BLINKS
1
TIME
2
TIMES
3
TIMES
4
TIMES
LED
GREEN
BLINKS
1
TIME
2
TIMES
3
TIMES
4
TIMES

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hrv150te

Table of Contents