Recovery; Defrost Mode; Specifications - Broan HRV150FL User Manual

Residental use only
Hide thumbs Also See for HRV150FL:
Table of Contents

Advertisement

Available languages

Available languages

1. YOUR UNIT AND ITS PURPOSE (
1.3 R
ecoVeRy
Your ventilation system is equipped with a heat recovery core that is designed specifically to control
excess humidity and reduce ventilation costs by recovering the heat energy from the exhausted air,
and using that same heat energy to warm the fresh air being supplied. This heat recovery process
is accomplished in such a way that the stale air is never mixed with the fresh air.
e
(
xample
in winteR
Stale air to outdoors
6°C/42°F
Fresh air from outdoors
0°C/32°F
1.4 d
m
efRost
When the outdoor temperature is below -5°C (23°F), heat recovery creates frost in the module.
To maintain proper operation, the unit is programmed to defrost the recovery module. The defrost
frequency varies according to the outdoor temperature. Defrost lasts 7 minutes (or 10 minutes if set
on "Extented Defrost"). During the defrost cycle, the unit shifts to maximum speed and the dampers
close.
After defrosting, the unit returns to the operating mode selected by the user.
1.5 s
pecifications
M
odel
W
idtH
H
eigHt
d
eptH
W
eigHt
e
lectricAl supply
p
oWer consuMption
)
VF0026
ode
Hrv150fl
30¼"
16½"
171∕
"
8
65
. (29.5
lb
120 v, 60 H
160
WAtts
cont
Hrv190fl
30¼"
16½"
171∕
"
8
)
65
. (29.5
kg
lb
120 v, 60 H
z
195
WAtts
5
'
)
d
Fresh air to building
16°C/61°F
Stale air from building
22°C/72°F
)