Installing The Magnetic Contact And Bolt Contact - Bosch SE 220 LSNi Installation Manual

Smartkey arming device
Table of Contents

Advertisement

Installing the SPE blocking element
Install the SPE blocking element using the appropriate kit and in accordance with the en-
closed installation notes.
Make sure the door cannot slam shut. The bolt of the SPE blocking element could oth-
!
erwise be damaged during start-up by a slamming door.
SPE blocking element variants and kits
Installation on the door or on the frame
Kit for on-the-door installation. In
the kit, a conventional magnet
contact can be used.
Bolt piece (installed on the frame)
Sleeve piece (installed on the door)
Installation example:
Spacers
Door

Installing the Magnetic Contact and Bolt Contact

Install the magnetic contact or bolt contact in accordance with the manufacturer's instructions.
The control unit will serve as a distributor for the contacts.
Installation Instructions
Kit for
glass doors
Installation example:
Glass
Bolt piece of the
blocking element
Fastening
bar of the
kit
Sleeve piece of the
blocking element
9
Installation on the door or on the frame
Bushing
Normal collar
Counterpiece
Installation example:
Counterpie-
ce/bushing
Frame
Door
Angled collar
Blocking
element
Collar