Installing the SPE blocking element
Install the SPE blocking element using the appropriate kit and in accordance with the en-
closed installation notes.
Make sure the door cannot slam shut. The bolt of the SPE blocking element could oth-
!
erwise be damaged during start-up by a slamming door.
SPE blocking element variants and kits
Installation on the door or on the frame
Kit for on-the-door installation. In
the kit, a conventional magnet
contact can be used.
Bolt piece (installed on the frame)
Sleeve piece (installed on the door)
Installation example:
Spacers
Door
Installing the Magnetic Contact and Bolt Contact
Install the magnetic contact or bolt contact in accordance with the manufacturer's instructions.
The control unit will serve as a distributor for the contacts.
Installation Instructions
Kit for
glass doors
Installation example:
Glass
Bolt piece of the
blocking element
Fastening
bar of the
kit
Sleeve piece of the
blocking element
9
Installation on the door or on the frame
Bushing
Normal collar
Counterpiece
Installation example:
Counterpie-
ce/bushing
Frame
Door
Angled collar
Blocking
element
Collar