Notes For Maintenance And Service; General; Inspection And Maintenance - Bosch SE 220 LSNi Installation Manual

Smartkey arming device
Table of Contents

Advertisement

General

Maintenance and inspection measures must be performed at specific intervals by appropriately
qualified personnel. Furthermore, the regulations of DIN VDE 0833 apply to all related work.

Inspection and Maintenance

Function test of the control unit tamper control function
Visual inspection of mounting/damage
Function test for the SPE blocking element
Function test for the SPE blocking element with bolt contact:
1. Activate the bolt contact when the door is closed.
The SPE blocking element bolt engages.
2. Place the bolt contact back on stand-by.
The SPE blocking element bolt disengages.
SPE blocking element function test with control unit (tamper contact open):
1. Remove the jumper from B1 and connect it to B3 on the control unit.
The SPE blocking element bolt engages.
The yellow LED on the control unit lights up.
2. Remove the jumper from B3 on the control unit.
The SPE blocking element bolt disengages.
The yellow LED on the control unit goes out.
3. Repeat steps 1 - 2 with the door closed to check the precise insertion of the SPE blocking e-
lement's bolt into the bolt-hole.
4. Reconnect the jumper to bridge B1 on the control unit once you have completed the function
test.
The yellow LED on the control unit's circuit board indicates the system's status as follows:
Yellow LED
Status
Off
System is OK
1 flash
Bolt will not engage.

Notes for Maintenance and Service

Required action
None
Check that the SPE blocking element and the
bolt-hole are correctly installed and con-
nected to the power supply.
Repeat the test.