Operating Problems During Normal Operation - Bosch SE 220 LSNi Installation Manual

Smartkey arming device
Table of Contents

Advertisement

Fault Elimination

Operating Problems During Normal Operation

Problem
Reader does not respond
when the key is held up to
the scanner.
No display on the reader, on-
ly an interval signal when the
key is held up to the scanner.
Area cannot be armed. Inter-
val signal is sounded imme-
diately after the system
status is displayed on the
reader.
Area cannot be armed. Inter-
val signal sounds for approx.
15 seconds after arming was
requested (= red LED
flashes).
Area cannot be armed. Inter-
val signal sounds for approx.
60 seconds after arming was
requested (= red LED
flashes).
Possible cause(s)
Key outside of scanner range.
Key not held up to the reader for
long enough.
Key button not pressed when key
was held up to the reader.
Metal objects located between key
and reader.
Key not/incorrectly programmed or
read in.
Key bypassed by security man-
ager.
Reader blocked. Incorrect code
entered repeatedly.
Open bolt or magnetic contact on
the SmartKey door.
User not authorized to arm the a-
rea.
Locking bolt does not engage
properly.
Open doors or windows in the de-
tection area.
In the case of multiple detection
areas: arming sequence not ad-
hered to.
If detection area has a block type
lock: block type lock not locked.
No code entered.
The "
" key was not pressed af-
ter the code was entered.
30
Elimination
Repeat the arming process after re-
moving any of the possible causes of
error.
Check possible causes of error or in-
form your security manager.
Block will be deactivated automati-
cally after 5 minutes.
Repeat the arming process after re-
moving any of the possible causes of
error.
Repeat the arming process after re-
moving any of the possible causes of
error.
Repeat the arming process after re-
moving any of the possible causes of
error.

Advertisement

Table of Contents
loading

Table of Contents