Example of Operation with 4 SmartKeys/Code Keypads

All SmartKeys/code keypads have equal arming and disarming rights.
1
Detection area
3

Disarming for "Forced Unlocking and Alarm Display"

!
The operator's attention must be drawn to the following points if this function has been
programmed in the EMA.
If the red LED on the reader flashes continuously after disarming, it means that the SmartKey is
signaling an intrusion alarm. It is recommendable to have a procedure in place to protect the op-
erator, e.g.: do not enter the area, call security or the police etc. The red LED will be deactivated
when the intrusion alarm system is reset.
If programmed, this function will immediately retract the SPE blocking element bolt when an ex-
ternal alarm is triggered and an optical signal (flashing red LED) will indicate this status to the
user when the external alarm is disarmed.
2
4
28
Arming:
Arming can occur with any SmartKey
once all the bolt contacts are closed
and the detection area is ready to be
activated. Arming will engage all SPE
blocking element bolts.
Disarming:
Any SmartKey can be used for disarm-
ing. Disarming will disengage all SPE
blocking element bolts.