Brocade VDX 6940-36Q and 6940-144S Specifications
Power (continued)
Maximum current
Typical power consumption
Maximum power consumption
Safety Compliance
•
CAN/CSA C22.2 No. 60950-1-07 including A1 / UL
60950-1-07, Ed. 2 including A1
•
CAN/CSA-C22.2 No. 60950-1 Second Edition
•
EN 60950-1 Second Edition +A1/A12
EMC
•
FCC Class A
•
ICES-003 Class A
•
VCCI-Class A
•
CE
Immunity
•
EN55024
Environmental Regulatory Compliance
RoHS-6 (with lead exemption) Directive 2002/95/EC
NEBS-Compliant
Standards Compliance
Brocade VDX 6940 products conform to the following Ethernet standards:
•
IEEE 802.1D Spanning Tree Protocol
•
IEEE 802.1s Multiple Spanning Tree
•
IEEE 802.1w Rapid Reconfiguration of Spanning Tree Protocol
•
IEEE 802.3 Ethernet
•
IEEE 802.3ad Link Aggregation with LACP
•
IEEE 802.3ae 10G Ethernet
•
IEEE 802.1Q VLAN Tagging
The following draft versions of the Data Center Bridging (DCB) and Fibre Channel over Ethernet (FCoE) standards are also supported on the
Brocade VDX 6940:
•
IEEE 802.1Qbb Priority-based Flow Control
•
IEEE 802.1Qaz Enhanced Transmission Selection
•
IEEE 802.1 DCB Capability Exchange Protocol (Proposed under the DCB Task Group of IEEE 802.1 Working Group)
•
FC-BB-5 FCoE (Rev 2.0)
8
Brocade VDX 6940-36Q
6 A at 100 VAC
7 A at 90 VAC
At 100 VAC 2.18 A, 215 W, 733.81 BTU/hr
At 200 VAC 1.12 A, 212 W, 723.57 BTU/hr
Input current calculated with 1 PSU; watts and
BTU/hour with 2 PSUs
At 100 VAC 2.84 A, 282 W, 962.5 BTU/hr
At 200 VAC 1.44 A, 276 W, 942 BTU/hr
Input current calculated with 1 PSU; watts and
BTU/hour with 2 PSUs
•
•
•
•
•
•
•
•
•
•
•
•
•
(continued)
Brocade VDX 6940-144S
6 A at 100 VAC
7 A at 85 VAC
At 100 VAC 3.288 A, 327 W, 1,116 BTU/hr
At 200 VAC 1.639 A, 321 W, 1,095 BTU/hr
Input current calculated with 1 PSU; watts and
BTU/hour with 2 PSUs
At 100 VAC 2.706 A, 512 W, 1,747 BTU/hr
At 200 VAC 1.375 A, 500 W, 1,706 BTU/hr
Input current calculated with 1 PSU; watts and
BTU/hour with 2 PSUs
IEC 60950-1 Second Edition +A1
GB 4943.1-2011 and GB9254-2008
CNS14336-1(99)
CSA/NRTL Certification
C-Tick
BSMI
KCC Class A
IEEE 802.1p Class of Service Prioritization and Tagging
IEEE 802.1v VLAN Classification by Protocol and Port
IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
IEEE 802.3x Flow Control (Pause Frames)
IEEE 802.3ab 1000BASE-T
IEEE 802.3z 1000BASE-X