Brocade VDX 6940-36Q and 6940-144S Specifications
Scalability Information*
Queues per port
DCB Priority Flow Control (PFC) classes
Maximum ACLs
Maximum ARP entries
Maximum IPv4 unicast routes
Maximum IPv6 unicast routes
DCB Priority Flow Control (PFC) classes
HA/ISSU
Mechanical
Enclosure
Environmental
Temperature
Humidity
Altitude
Shock
Vibration
Airflow
Power
Power supplies
Power inlet
Input voltage
Input line frequency
Inrush current
* Please refer to the latest version of the release notes for the most up-to-date scalability numbers supported in software.
8
8
10,000
84,000
12,000
3,000
8
ISSU fully supported
Front-to-rear, rear-to-front airflow; 1U (6940-36Q) and 2U (6940-144S), 19-inch EIA-compliant;
power from non-port side
Brocade VDX 6940-36Q
Operating: 0°C to 40°C (32°F to 104°F)
Non-operating and storage: −25°C to 70°C
(−13°F to 158°F)
Operating: 5% to 93% at 50°C (122°F)
Non-operating and storage: 10% to 95% at
60°C (140°F)
Operating: 0 to 3,000 m (9,842 ft.)
Non-operating and storage: 0 to 12,000 m
(39,370 ft.)
Operating: 15 G, 11 ms, half-sine wave
Non-operating and storage: 33 G, 11 ms, half-sine
wave, 5/ea axis, and 33 G 6 ms, trapezoidal,
1/ea axis
Operating: 1 G sine, 0.5 gms random,
5 to 500 Hz
Non-operating and storage: 2.4 G sine, 1.1 gms
random, 5 to 500 Hz
Maximum: 159 CMH (94 CFM)
Minimum: 65 CMH (38 CFM)
Two internal, redundant, field-replaceable, load-
sharing power supplies
C13
100 to 240 V or 48 V DC
50 to 60 Hz
30 A peak at cold start and 50 A peak at warm
start for <10 ms, 10 A peak for cycles 10 ms to
150 ms, <7 A peak for >150 ms
(continued)
Brocade VDX 6940-144S
Operating: 0°C to 40°C (32°F to 104°F)
Non-operating and storage: −25°C to 70°C
(−13°F to 158°F)
Operating: 5% to 93% at 50°C (122°F)
Non-operating and storage: 10% to 95% at 60°C
(140°F)
Operating: 0 to 3,000 m (9,842 ft.)
Non-operating and storage: 0 to 12,000 m
(39,370 ft.)
Operating: 15 G, 11 ms, half-sine wave
Non-operating and storage: 33 G, 11 ms, half-sine
wave, 5/ea axis, and 33 G 6 ms, trapezoidal,
1/ea axis
Operating: 1 G sine, 0.5 gms random,
5 to 500 Hz
Non-operating and storage: 2.4 G sine, 1.1 gms
random, 5 to 500 Hz
Maximum: 370 CMH (218 CFM)
Minimum: 95 CMH (56 CFM)
Two internal, redundant, field-replaceable, load-
sharing power supplies
C13
100 to 240 V or 48 V DC
50 to 60 Hz
40 A peak at either cold or warm start <10 ms,
10 A peak for cycles 10 ms to 150 ms, <7 A peak
for >150 ms
7