Water Piping Installation - Heat Pump Unit & Tank - Sanden GS3-45HPA-US Installation Manual

Heat pump water heater with natural refrigerant
Hide thumbs Also See for GS3-45HPA-US:
Table of Contents

Advertisement

Note:
The entire system is set up and fully functional when supplied. Once all the water and
electric connections have been made, the system will operate automatically provided that
mains power is available.
The only adjustments to the unit are to set the desired hot water supply temperature & set
the current time on the operation panel under the top housing cover, especially if the block
out time setting is desired. See Set point adjustment, current time setting, and block out
time section on page 19.
Figure 5: Heat pump installation example and dimensions
Attach the drain elbow to the drain opening located on the bottom of the heat pump
unit. The drain elbow is included in the installation kit for the heat pump unit.
Attach a drain hose with 5/8 inch (16mm) of inner diameter to the drain elbow to guide
the drained water to an appropriate drain.
Water Piping Installation – Heat Pump Unit & Tank
All piping that connects to the water supply must be installed by a licensed contractor.
The water supplied to the system must comply with the potable water quality standard.
Use of water that does not comply with this standard could result in a malfunction of
the system.
Description
PH
Maximum
6.0
Levels
to
9.0
The water supply must have a pressure of 29 PSI (200 kPa) or higher.
A drain trap must be installed on the drain pipe if water is to be drained to a drain pan.
TDS
Total
(Total
Hardness
Dissolved
(calcium Ion
Solids)
concentration)
Up to
Up to
500 ppm
200ppm or
12 grains
hardness
Sanden Heat Pump – Installation Manual 
Aluminium
Chlorides
Up to
Up to
0.2 ppm
200
ppm
Page 7 of 36 
Copper
Iron
Manganese
Up to
Up
Up to
1.0
to
0.05 ppm
ppm
0.3
ppm
Zinc
Up
to 5
ppm

Hide quick links: