Sanden GAUS-160FQS Owner's Manual

Hide thumbs Also See for GAUS-160FQS:

Advertisement

Owner's manual
Covering model numbers for residence
GAUS-160FQS
GAUS-250FQS
GAUS-300FQS
GAUS-315FQS
GAUS-315FQV
Heat Pump Unit
GAU-A45HPC
This appliance is not to be used by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction.
Children being supervised not to play with the appliance.
Sanden Heat Pump – Owner's Manual
20892940(K)
Page 1 of 20

Advertisement

Table of Contents
loading

Summary of Contents for Sanden GAUS-160FQS

  • Page 1: Page Title

    This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. Children being supervised not to play with the appliance. Sanden Heat Pump – Owner’s Manual 20892940(K) Page 1 of 20...
  • Page 2: Table Of Contents

    No liability can be accepted for any consequences that may arise as a result of its application. No liability can be accepted for any consequences that may arise as a result of its application. Sanden is in a process of continuous improvement, therefore specifications may be different to those referenced in this manual –...
  • Page 3: Introduction

    Introduction The Sanden Heat Pump Water Heater System has been designed using the latest refrigeration technology to remove the heat from the air to heat water. The refrigerant we use is CO which does not contribute to global warming so it allows us to help keep a clean healthy earth for future generations.
  • Page 4 Do not touch the tap while hot water is being supplied Sanden Heat Pump – Owner’s Manual Page 4 of 20...
  • Page 5 ・Please contact the Dealer about insulating the pipes. ・Contact the Dealer for repair. Sanden Heat Pump – Owner’s Manual Page 5 of 20...
  • Page 6 · Ensure not to put anything around the heat pump unit. not bother your neighbours. Could result in poor performance and unexpected problems. In the winter in particular please pay attention to any snow coverage. Sanden Heat Pump – Owner’s Manual Page 6 of 20...
  • Page 7 Sanden Heat Pump – Owner’s Manual Page 7 of 20...
  • Page 8: Installation Details

    Installation details This Sanden Eco Hot water Heat Pump System must be installed by a licensed person in consideration of the following standards and regulations: AS/NZS3500 National plumbing and drainage code hot water supply systems – acceptable solutions HB 263-2004 Heated water systems plumbing industry commission...
  • Page 9: Trouble Shooting Guide

    If the system is equipped with freeze protect heaters, also do not turn off the power supply to the heaters. Failure to do so may cause the pipes to crack, due to freezing. Sanden Heat Pump – Owner’s Manual Page 9 of 20...
  • Page 10: Error Codes

    Compressor booting error Water circuit error Compressor revolution error High water outlet error Refrigerant leakage error Water pump error Main PCB error Fan motor locked Control PCB error Discharged temperature error Sanden Heat Pump – Owner’s Manual Page 10 of 20...
  • Page 11: Removing Air From The System

    Water drain plugs Unit. Close the plugs after no air is confirmed in the water supply. Then connect power to the Heat Pump Unit. Open Faucets. Open The drain plug Sanden Heat Pump – Owner’s Manual Page 11 of 20...
  • Page 12: Electrical Connections

    Select the electrical supply mode that best suits the customer’s hot water consumption. The type of off-peak connection may need to be changed if hot water supply is not maintained as required. Figure 5: Outline of electrical system connections Sanden Heat Pump – Owner’s Manual Page 12 of 20...
  • Page 13: How To Connect Power Line And Thermistor Cable

    Connect the thermistor cable line to the terminal block. Hold the thermistor cable with the code clip and conduit clip Attach the piping cover back on the heat pump unit. Figure 6: Connect power cables 25mm or less Sanden Heat Pump – Owner’s Manual Page 13 of 20...
  • Page 14: Water Supply Quality

    Sanden Heat Pump – Owner’s Manual Page 14 of 20...
  • Page 15: Technical Data

    49 kg MAX HEAT OUTPUT 6.0 kW MAX RATED POWER INPUT 2.3 kW Circuit Breaker Size Design Pressure(High/Low) 14/9 MPa Protection Raining Class IPX4 MAX Operating water Pressure 700 kPa Sanden Heat Pump – Owner’s Manual Page 15 of 20...
  • Page 16 Hot water storage tank unit REFER Drawing provided with tank Sanden Heat Pump – Owner’s Manual Page 16 of 20...
  • Page 17 315L 160L 250L 300L Sanden Heat Pump – Owner’s Manual Page 17 of 20...
  • Page 18: Warranty Policy

    Sanden Heat Pump Water Heater System literature. Warranty Exclusions 1. Repair and replacement work will be carried out as set out in the Sanden Heat Pump Water Heater System warranty. However the following exclusions may void the warranty and may incur additional service charges and/or cost of parts: 2.
  • Page 19: Warranty Period

    Subject to the Warranty Conditions and Exclusions stated above, your Sanden Heat Pump Water Heater System is warranted in a Residential application as follows: Heat pump unit – Sanden warrants all parts labour on the SANDEN water heater system for a period of 6 (Six) years from date of installation.