Installing the Chassis
Statement 1006—Chassis Warning for Rack-Mounting and Servicing
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions
to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top with
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing
Step 1
Slide the power supply end of the chassis onto the bottom-support rails that are installed on the rack.
Be sure that the sides of the chassis by the power supplies clips into the chassis stops on the bottom-support rails and
the front-mount brackets come in contact with the rack (see the following figure).
the heaviest component at the bottom of the rack.
the unit in the rack.
Installing the Chassis in a Four-Post Rack
Cisco Nexus 9336PQ ACI-Mode Switch Hardware Installation Guide
19