0VT Output settings
This menu makes it possible to configure the parameters of the Controller outputs.
0
v
t
PV
---
SV
Select reference signal for alarm
i. A
r
PV
1
0
SV
Select reference signal for
A
2.
r
PV
alarm 2
0
SV
A
3.
r
PV
Select reference signal for alarm 3
0
SV
AI. t
PV
Alarm type 1
0
SV
A
2.
t
PV
Alarm type 2
0
SV
A
3.
t
Alarm type 3
PV
0
SV
K
b.
F
HB alarm function
PV
4
SV
81801G_MHW_1200-1300_07-2011_ENG
Second menu to set up
A1. T
A2. T
A3. T
0
1
2
3
4
5
6
7
By adding the following figures to the value in the table it is possible
to enable a series of supplementary functions:
+8:
+16:
+32:
+64:
By adding the following figures to the value in the table it is possible to
enable a series of supplementary functions:
+0:
+4:
+8:
+12:
+16:
NOTE: The HB alarm is disabled if assigned to a rapid output (except
*) minimum setting is fixed at 12% of amperometric full scale
**) cAs type 0 without reference to cycle time
A 1. R
A2. R
Variable to compare
A3. R
0
PV (process variable)
1
SV (active setpoint)
2
PV (process variable)
Direct
(high limit)
Inverse (low limit)
Direct
Inverse
Direct
Inverse
Direct
Inverse
Direct
Inverse
to disable on power up until first interception
to latch alarm.
KY. 1 (2 / 3 ) menu [FG = delay time for alarm trip [0..999] sec.
(excluding symmetrical absolute)
KY. 1 (2 / 3 ) menu [FG = delay time for alarm trip [0..999] min.
(excluding symmetrical absolute)
Function description
KB. F
0
Relay, logic output: alarm active on load current level
lower than setpoint during the ON time of the control
output.
1
Relay, logic output: alarm active on load current level
higher than setpoint during the OFF time of the control
output.
2
Alarm active if one of functions 0 and 1 is true
(OR logic (*)
3
Continuous heat alarm (**)
7
Continuous cool alarm (**)
assigned to output OUT1 (only for KB. F = 0,1,2).
assigned to output OUT2 (only for KB. F = 0,1,2).
assigned to output OUT3 (only for KB. F = 0,1,2).
assigned to output OUT4 (only for KB. F = 0,1,2).
inverse HB alarm.
codes 3 and 7)
Alarm setpoint
AL
AL only absolute
AL only realtive and
referred to SP
(with multiset function)
Normal
Absolute/Relative
Symmetrical
to active setpoint
(window)
Absolute
Normal
Absolute
Normal
Relative
Normal
Relative
Normal
Absolute
Symmetrical
Absolute
Symmetrical
Relative
Symmetrical
Relative
Symmetrical
25