Toshiba MCY-MHP0404HS-E Service Manual page 65

Multi type
Table of Contents

Advertisement

To select another line address
5
Push the
button to return to step
• After returning to step
6
Push the
button to finish the procedure.
Changing the indoor unit address using a remote controller
To change an indoor unit address using a wired remote controller.
The method to change the address of an individual indoor unit (the indoor unit is paired with a wired
remote controller one-to-one), or an indoor unit in a group.
(The method is available when the addresses have already been set automatically.)
(Execute it while the units are stopped.)
1
Push and hold the
(If 2 or more indoor units are controlled in a group, the first indicated UNIT No. is that of the head unit.)
2
Push the
change if 2 or more units are controlled in a group. (The fan and louvers of the selected indoor
unit are activated.)
(The fan of the selected indoor unit is turned on.)
3
Push the TEMP.
4
Push the TIME
to that you want.
5
Push the
button.
6
Push the
change.
4
Repeat steps
7
Push the
8
If the addresses have been changed correctly, push the
AMP Air Conditioning
2
, select another line address and check the indoor unit addresses of the line.
Finish
,
, and
buttons at the same time for more than 4 seconds.
button (left side of the button) repeatedly to select an indoor unit number to
/
buttons repeatedly to select
/
buttons repeatedly to change the value indicated in the SET DATA section
button (left side of the button) repeatedly to select another indoor UNIT No. to
6
to
to change the indoor unit addresses so as to make each of them unique.
button (left side of the button) to check the changed addresses.
2
.
64
78
www.ampair.co.uk | sales@ampair.co.uk
for CODE No..
button to finish the procedure.