Control mode
1.Major general technical parameters
1 Conditionings for operation: Ambient temperatures: (-7 - +45 ℃), relative humidity
(30 - 95%).
2 Remote receiver distance: 8 m.
3 Remote receiver angle: In the distance 5M, over 60 degrees.
4 Temperature control accuracy: ±1℃.
5 Time error: Less than 3%.
6 The power supply for the air conditioner is a.c 220~240V, 50Hz, with its fluctuation
in the range of (160 – 264 V).
2、Display of the indoor unit
Timer Indicator :It lights up during the setting timer mode.
Run Indicator:It is on during operation. It flashes within 10s after the sleep mode
has been setted.
Sleep indicator:It lights up when the sleep mode is being setted and within 10s
after the sleep mode has been setted.
Compressor indicator:It lights up when compressor is running
All the displays will be Off after the sleep mode has been setted for
10s unless the sleep mode is canceled.
Displaying Scheme:
. Timer: the timer value is displayed according to the data from the remote controller.
1
2.Temperature: the setting temperature value is displayed according to the data from
the remote controller. "— —" is displayed when dehumidifying mode and air blowing
mode value.
3.Display of error codes:
An error code is displayed according to the signal from the indoor CPU. The error
code will flash for 5 seconds while displayed.
Error codes will be displayed at the displaying area for setting temperature.
3. Sleep
3..1 In the heating, cooling or dehumidifying mode, press the "Sleep" button on the
remote controller to start or cancel the sleep function in turn, and at the same time
the sleep icon on the display screen will be on or off accordingly.
3.2In the heating mode, the set temperature will decrease by 1℃ one hour after the
sleep function is started. After 3 more hours operation, the temperature decreases by
3℃ further.
3.3 In the cooling mode, the setting temperature will rise by 1℃ one hour after the
sleep function is started. After 1 more hours operation, the temperature decreases by
1℃ further. If
T
room t
4.1 Automatic run mode
Press the emergency button or use remote controller to set this mode. .
For heating pump machine:
M
O
D
E
M
O
D
E
the setting temperature do not change.
>26℃,
A
A
13
S
-
1
8
U
R
4
S
T
V
S
-
1
8
U
R
4
S
T
V
U
H
1
U
H
1