AudioCodes MediaPack MP-11 Series Troubleshooting Manual page 14

Cpe
Hide thumbs Also See for MediaPack MP-11 Series:
Table of Contents

Advertisement

Trunk Icon Status
Color
Alarm
Gray
Trunk
Disabled
Red
Loss of
Signal
(LOS)
or
Loss of
Frame
(LOF)
Yellow
Remote
Alarm
Indication
(RAI)
Orange
D-Channel
Troubleshooting Guide
Table 3-1: No Access or Ping to Gateway
Possible Cause
The Trunk is not
Configure the Trunk in the Web interface's 'Trunk
configured
Settings' page.
Note: If the 'Protocol Type' field displays 'NONE' (i.e.,
no protocol type selected) and no other trunks have
been configured, after selecting a PRI protocol type, you
must reset the device.
LOS: Indicates a
To clear the LOS alarm, ensure the following:
physical problem.
1
LOF: Indicates that
the Trunk port is
not receiving
2
framing, or has lost
synchronization on
the received
3
framing.
4
To clear the LOF alarm, ensure the following:
1
2
3
4
The far-end
Contact the PBX/PSTN provider and report this alarm to
equipment (e.g.,
resolve the problem.
PBX) has a
problem with the
signal that it
receives from the
local equipment.
--
To clear this alarm, perform the following:
1
2
3
4
MediaPack, Mediant 1000, Mediant 2000
Solution
The E1/T1 cable is connected securely between the
device's PSTN ports and the service provider's
equipment (PSTN network).
The E1/T1 trunk cable is not physically damaged; if
so, replace the cable.
The E1/T1 cable is crimped correctly (refer to the
figure above).
The correct E1/T1 cable is used (crossover /
straight). If a straight cable is being used and LOS is
still present, try a crossover cable, and vice versa.
The PBX and device are configured to use the same
Trunk type (E1 or T1).
The Framing method of the PBX and device is
identical.
The Line code of the PBX and device is identical.
The clocks are synchronized (refer to ''How Do I
Check for E1/T1 Clock Slips'' on page 15).
Ensure that the correct ISDN variant is selected.
If the device is configured as User side, ensure that
the PBX/PSTN is configured as Network side, and
vice versa.
Ensure that the Framing method configured for the
device is the same as the Framing method on the
PBX/PSTN.
If the D-channel alarm isn't cleared, contact the
AudioCodes Technical Support team and provide
them with the ini file of the device and a PSTN trace
(refer to ''CLI Debug Recording'' on page 72).
14
Document #: LTRT-57601

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mediant 2000Mediant 1000Mediant 600Mediapack mp-124

Table of Contents