KERN 572 KB Operating Instructions Manual

Electronic precision and platform balances

Advertisement

Quick Links

GB

Table of contents

:
1
MODE - MENUE __________________________________________________________ 26
2
Technical data _____________________________________________________________ 27
2.1
KERN 572 __________________________________________________________________ 27
2.2
KERN 573 __________________________________________________________________ 28
2.3
KERN KB __________________________________________________________________ 29
2.4
KERN DS ___________________________________________________________________ 29
3
Fundamental information (general) ___________________________________________ 30
3.1
Intended use_________________________________________________________________ 30
3.2
Inappropriate use ____________________________________________________________ 30
3.3
Guarantee __________________________________________________________________ 30
3.4
Monitoring the test substances__________________________________________________ 30
4
Fundamental safety information ______________________________________________ 30
4.1
4.2
Staff training ________________________________________________________________ 30
5
Transport and storage _______________________________________________________ 30
5.1
Acceptance check ____________________________________________________________ 30
5.2
Packaging___________________________________________________________________ 31
6
Unpacking, installation and commissioning _____________________________________ 31
6.1
Place of installation, place of use ________________________________________________ 31
6.2
Unpacking __________________________________________________________________ 31
6.2.1
Installation _______________________________________________________________________ 31
6.3
Mains supply ________________________________________________________________ 31
6.4
Connecting peripheral equipment _______________________________________________ 31
6.5
Initial start-up _______________________________________________________________ 31
6.6
Adjustment _________________________________________________________________ 32
6.7
Adjusting ___________________________________________________________________ 32
6.7.1
Adjusting for verification (KERN 573) _________________________________________________ 32
6.8
Verification _________________________________________________________________ 32
24
KERN 572/573/KB/DS
Version 4.10 12/2004
Operating Instructions
Electronic Precision and Platform Balances
572/573/KB/DS-BA-defsi-04410

Advertisement

Table of Contents
loading

Summary of Contents for KERN 572 KB

  • Page 1: Table Of Contents

    Place of installation, place of use ________________________________________________ 31 Unpacking __________________________________________________________________ 31 6.2.1 Installation _______________________________________________________________________ 31 Mains supply ________________________________________________________________ 31 Connecting peripheral equipment _______________________________________________ 31 Initial start-up _______________________________________________________________ 31 Adjustment _________________________________________________________________ 32 Adjusting ___________________________________________________________________ 32 6.7.1 Adjusting for verification (KERN 573) _________________________________________________ 32 Verification _________________________________________________________________ 32 572/573/KB/DS-BA-defsi-04410...
  • Page 2 Operation _________________________________________________________________ 33 7.1 Display control panel _______________________________________________________ 33 Operation ___________________________________________________________________ 34 Interface RS 232 C ___________________________________________________________ 38 RS 232 C Data output via interface RS 232 C _____________________________________ 38 7.4.1 There are 4 methods for the data output via RS 232 C______________________________________ 38 7.4.2 Description of the data transfer________________________________________________________ 39 Printer _____________________________________________________________________ 39...
  • Page 3: Mode - Menue

    1 MODE - MENUE MODE CAL? PLACE CAL Mode WEIGHT Manufactur Setting: COUNT? REF=1 N/ Y Mode Mode REF=5 Count?: Mode REF10: REF=10 Mode 9600bd: REF=20 Preselect Mode Units?: g/kg Mode Preselect Tare? 0.000g Mode Autotare: Mode Fast: AUTOTARE? Mode FAST Mode AUTO OFF?
  • Page 4: Technical Data

    2 Technical data 2.1 KERN 572 KERN 572-33 572-35 572-45 572-49 572-57 Readout 0,01 g 0,01 g 0,1 g 0,1 g 0,2 g Weighing range 1.010 g 1210 g 10.100 g 12.100 g 20.100 g Taring range (subtractive) 1.010 g 1210 g 10.100 g...
  • Page 5: Kern 573

    2.2 KERN 573 KERN 573-46 573-52 Class of accuracy Readout (d) 0,1 g 0,2 g Verification value (e) Weighing range (max.) 6500 g 13000 g Minimum load (Min) Taring range (subtractive) 6500 g 13000 g Reproducibility 0,1 g 0,2 g Linearity ±0,2 g...
  • Page 6: Kern Kb

    2.3 KERN KB KERN KB800-2 KB8000-1 Readout 0,01 g 0,1 g Weighing range 810 g 8.100 g Taring range (subtractive) 810 g 8.100 g Reproducibility 0,01 g 0,1 g Linearity ±0,03 g ±0,3 g Minimum weight for counting parts 0,03 g...
  • Page 7: Fundamental Information (General)

    For this purpose, the answerable user must define a suit- able interval as well as the nature and scope of this check. Information is available on KERN’s home page (www.kern-sohn.com) with regard to the monitoring of balance test substances and the test weights required for this.
  • Page 8: Packaging

    Electric power supply is by means of the external mains supply circuit. The printed voltage level must comply with the local voltage. Only use original KERN mains supply circuits. The use of other makes is subject to approval by Kern. Connecting peripheral equipment The balance must be disconnected from the mains before connecting or disconnecting additional equipment (printer, PC) to or from the data interface.
  • Page 9: Adjustment

    Adjustment procedure: Check that the surrounding conditions are stable. A short warm-up time of about 15 minutes is recommended for stabilisation. 6.7.1 Adjusting for verification (KERN 573) General Information: Prior to the procedure of verification the balance has to be adjusted.
  • Page 10: Operation

    7 Operation 7.1 Display control panel Keyboard ON / OFF Print weighing result in MODE: No / descending in % and counting mode: Form reference in MODE: Yes / ascending MODE configuration (see mode structure diagram page 2) Formula weighing in MODE: to left Change g-pieces Unit changeover...
  • Page 11: Operation

    7.2 Operation WIEGEN mit TARIEREN/WEIGHING with TARE During weighing in a certain weight amount of a product is to be filled into a weighing container with- out the tare weight of the container being weighed. The weighing container is excluded from consid- eration by using TARE and thus only the measured value of the product is indicated.
  • Page 12 572/573/KB/DS-BA-defsi-04410...
  • Page 13 JUSTIEREN/ADJUST The balance must be adjusted at its place of installation before initial use and at regular intervals. Please observe the warm-up time referred to in the chapter on ”Commissioning”. It is essential to avoid jarring and disturbances during the adjusting procedure. TARAVORABZUG/PRESELECT TARE The known tare value of a weighing container can be “deducted”...
  • Page 14 572/573/KB/DS-BA-defsi-04410...
  • Page 15: Interface Rs 232 C

    Baud rate adjustable to 2400, 4800 and 9600 baud (default), 19200 baud Sup-D- 9 pol. is necessary . When working with an interface correct operation is secured only if the corresponding KERN-interface- cable (max. 2m) is used. Description of the jack Sup-D- 9 pol.
  • Page 16: Description Of The Data Transfer

    7.4.2 Description of the data transfer Structure of each data transfer: Without Numerator: Bit-Nr. Blank or % in the range of zero point. B, 0, , g: Blank or weighing value with unit, depending on the load on the weighing plate. Carriage Return Line Feed With Enumerator:...
  • Page 17: Maintenance, Upkeep, Disposal

    Loose sample residue/powder can be removed carefully using a brush or hand vacuum cleaner. Remove any spilt material to be weighed immediately. Maintenance, upkeep The device may only be opened by trained service engineers authorised by KERN. Disconnect from the mains supply before opening. Disposal The operating company shall dispose of the packaging and the device in compliance with the valid national or regional law of the operating location.
  • Page 18: Declaration Of Conformity

    EN 61000-3-3: 1995 + A1: 1998 + A1/A2 1998 +A2:2001 + A14 2000 If a change is made to the above mentioned appliances without consulting KERN this declaration will become invalid. Date: 07/01/2004 Signature: Gottl. KERN & Sohn GmbH Management Gottl.
  • Page 19 Dichiariamo con ciò che il prodotto al quale la presente dichiarazione si riferisce è confor- me alle norme di seguito citate. Balance lines: Mark applied EU Directive Standards 89/336EEC EMC EN45501 EN55022 Date: 03.06.2004 Signature: Gottl. KERN & Sohn GmbH Management Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-07433/9933-0,Fax +49-074433/9933-149 572/573/KB/DS-BA-defsi-04410...
  • Page 20 Questa dichiarazione sarà valida solo se accompagnata dal certificato di conformità della parte nominale. Model: EU Directive Standards EC-type-approval Issued by certificate no. 90/384/EEC EN45501 D04-09-019 Date: 03.06.2004 Signature: Gottl. KERN & Sohn GmbH Management Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72336 Balingen, Tel. +49-07433/9933-0,Fax +49-074433/9933-149 572/573/KB/DS-BA-defsi-04410...

This manual is also suitable for:

573 kb572 ds573 ds

Table of Contents