Maintaining The Pinning Order; Redistributing Host Interfaces; Verifying The Fabric Extender Configuration - Cisco Nexus 5000 Series Configuration Manual

Nx-os layer 2 switching configuration guide, release 5.0(3)n1(1)
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

Configuring the Fabric Extender

Maintaining the Pinning Order

The pinning order of the host interfaces is initially determined by the order in which the fabric interfaces were
configured. In this example, four fabric interfaces were configured in the following order:
switch# show interface ethernet 1/35 fex-intf
Fabric
Interface
---------------------------------------------------
Eth1/35
switch# show interface ethernet 1/33 fex-intf
Fabric
Interface
---------------------------------------------------
Eth1/33
switch# show interface ethernet 1/38 fex-intf
Fabric
Interface
---------------------------------------------------
Eth1/38
switch# show interface ethernet 1/40 fex-intf
Fabric
Interface
---------------------------------------------------
Eth1/40
The next time that you reboot the Fabric Extender, the configured fabric interfaces are pinned to the host
interfaces in an ascending order by port number of the fabric interface. If you want to configure the same
fixed distribution of host interfaces without restarting the Fabric Extender, enter the fex pinning redistribute
command.

Redistributing Host Interfaces

You can redistribute the host interfaces on the Fabric Extender. Enter the fex pinning redistribute FEX-number
command to redistribute the host connections. The range of the FEX-number is from 100 to 199.
This example shows how to redistribute the host interfaces on a Fabric Extender:
switch# fex pinning redistribute 101
The fex pinning redistribute command disrupts all the host interface ports of the Fabric Extender.
Caution

Verifying the Fabric Extender Configuration

To display configuration information about the defined interfaces on a Fabric Extender, perform one of the
following tasks:
FEX
Interfaces
Eth101/1/12
Eth101/1/11
Eth101/1/8
Eth101/1/7
Eth101/1/4
Eth101/1/3
FEX
Interfaces
Eth101/1/24
Eth101/1/23
Eth101/1/20
Eth101/1/19
Eth101/1/16
Eth101/1/15
FEX
Interfaces
Eth101/1/36
Eth101/1/35
Eth101/1/32
Eth101/1/31
Eth101/1/28
Eth101/1/27
FEX
Interfaces
Eth101/1/48
Eth101/1/47
Eth101/1/44
Eth101/1/43
Eth101/1/40
Eth101/1/39
Cisco Nexus 5000 Series NX-OS Layer 2 Switching Configuration Guide, Release 5.0(3)N1(1)
Maintaining the Pinning Order
Eth101/1/10
Eth101/1/9
Eth101/1/6
Eth101/1/5
Eth101/1/2
Eth101/1/1
Eth101/1/22
Eth101/1/21
Eth101/1/18
Eth101/1/17
Eth101/1/14
Eth101/1/13
Eth101/1/34
Eth101/1/33
Eth101/1/30
Eth101/1/29
Eth101/1/26
Eth101/1/25
Eth101/1/46
Eth101/1/45
Eth101/1/42
Eth101/1/41
Eth101/1/38
Eth101/1/37
257

Advertisement

Table of Contents
loading

Table of Contents