COREbar™ 4 QRG
EN
This product has an auto-ranging power supply that can work with an input
AC Power
voltage range of 100–240 VAC, 50/60 Hz.
To eliminate wear and improve its lifespan, during periods of non-use
completely disconnect from power via breaker or by unplugging it.
Power Linking
For the maximum number of COREbar™ 4 products that you can power link
at each voltage, see the sticker on the product or the User Manual.
1. Disconnect the product from power.
Fuse
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
Replacement
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and
replace with a fuse of the exact same type and rating.
5. Re-insert the fuse holder and reconnect power.