Steps
9.Remove the valves
Remove the 2 screws fixing the gas valve and
unsolder the welding point between the gas
valve and the air-return pipe to remove the
gas valve.
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid
valve to the Y-type pipe to remove the liquid
valve.
10.Remove compressor
Remove the foot nuts on the compressor and
then remove the compressor.
Procedure
liquid
valve
gas valve