Lennox LNFS2610 Installation Manual

Lennox LNFS2610 Installation Manual

Split wall-mounted type room air conditioners

Advertisement

Australia 13 23 50 New Zealand 0800 653 330
Web www.lennoxaus.com.au

INSTALLATION MANUAL

FOR ROOM

AIR CONDITIONER

(Split Wall-Mounted Type)
For MODELS –
FIXED SPEED
INVERTERS
LNFS2610
LNIV2610
LNFS3510
LNIV3510
LNFS5110
LNIV5010

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LNFS2610 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lennox LNFS2610

  • Page 1: Installation Manual

    INSTALLATION MANUAL FOR ROOM AIR CONDITIONER (Split Wall-Mounted Type) For MODELS – FIXED SPEED INVERTERS Australia 13 23 50 New Zealand 0800 653 330 LNFS2610 LNIV2610 Web www.lennoxaus.com.au LNFS3510 LNIV3510 LNFS5110 LNIV5010...
  • Page 2: Safety Precautions

    SAFETY PRECAUTIONS SELECT THE BEST LOCATION • Please read this installation manual completely before Indoor Unit WARNING installing the product. • Avoid locating the unit near a heat source. 1) Install strictly in accordance with these instructions. • If the power cord is damaged, replacement work shall be •...
  • Page 3: Indoor Unit

    INDOOR UNIT SELECT THE BEST LOCATION (continued) Name of Accessory Quantity supplied 1. FITTING THE INSTALLATION PLATE Installation Plate Clip Anchor 5-8 (depending on models) NOTE: The mounting wall should be strong and solid enough Self-tapping Screw AST3.9 x 2.5 5-8 (depending on models) to prevent it from vibrating.
  • Page 4 3. CONNECTIVE PIPE AND DRAINAGE INSTALLATION 4. CONNECTING THE CABLE TO THE INDOOR UNIT Drainage Electrical Work Connecting the cable to the indoor unit 1. Run the drain hose sloping downward. Do not install the Electric safety regulations for the initial installation: NOTE: Before performing any electrical work, turn off the drain hose as illustrated in the diagrams (see right).
  • Page 5: Outdoor Unit

    OUTDOOR UNIT 3. REFRIGERANT PIPE CONNECTION Flaring 1. OUTDOOR INSTALLATION PRECAUTIONS Ob l i q ue Roughnes s Burr 1. Cut a pipe with a pipe cutter. 2. Remove fl are nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr •...
  • Page 6 5. After the evacuation is complete, fully close the handle Lo of the manifold valve and stop the operation of the 5. AIR PURGING AND TEST OPERATION vacuum pump. • Evacuate for 15 minutes or until the compound meter indicates -76cmHg (-1.0 x 10 Pa).