Download Print this page

Lennox LNINV2610 Service Manual page 67

Refrigerant r410a

Advertisement

Steps
6.Remove vertical louver
1
Loosen the clasps connecting vertical
louver with bottom case.
2
Remove the vertical louver.
7.Remove electric box
1
Disconnect the indoor pipe tempera-
ture sensor.
2
Remove the screw of the electric box.
3
Remove the screws at the joint of
ground wire and evaporator.
Procedure
clasps
vertical louver
Heat exchanger
thermistor
screw
screws
Ground Wire

Advertisement