Installation Checklist - Howe 1000-RLE Installation & Service Manual

Rapid freeze ice flaker
Table of Contents

Advertisement

 
 
Installation Checklist
 
1. Has the ambient temperature been verified between 50°F – 100°F? 
(see Location Requirements p.3) 
2. Has the incoming water temperature been verified between 45°F – 90°F? 
(see Water Supply Requirements p.3) 
3. Has the water supply pressure been verified between 20 PSIG and 60 PSIG? 
(see Water Supply Requirements p.3) 
4. Has the filtered water supply been verified as not RO water? 
(see Water Supply Requirements p.3) 
5. Has the Ice Flaker been located near a floor sanitary sewer drain? 
(see Drain Water Piping Requirements p.4) 
6. Have the EPR and Suction Line Heat Exchanger been installed correctly? 
(see Suggested Refrigerant Piping Diagram p.6) 
7. Have all the refrigeration lines been sufficiently insulated? 
(see Refrigerant Pipework Insulation Requirements p.7) 
8. Has the Condensing Unit been mounted properly? 
(see Condensing Unit Rigging and Mounting p.8) 
9. Has the system been leak tested properly? 
(see Leak Testing p.9) 
10. Has the system been evacuated properly? 
(see Evacuation p.10) 
11. Have the Photo Eye sensors been connected? 
 
(see Field Wiring p.10) 
12. Has the system been charged properly? 
(see Refrigerant Charging Instructions p.11)
 
 