2.9
Redundant power supply module
The server system can support up to two 800W 80Plus Platinum redundant power supply
module. You can purchase and install the second redundant power supply module if there is
only one power supply module in your system.
•
•
•
To install the second redundant power
supply module:
1.
Press the latch to the left (A).
2.
Remove the metal cover from the
chassis (B).
3.
Prepare the second redundant power
supply module.
Ensure to remove the protection cap before installation.
4.
Carefully insert the replacement power
supply module into the chassis.
5.
Push the power supply module in
place (C).
2-24
Ensure that the system is turned off before removing any components.
Touch any metal surface to release static electricity.
Use power supply module with the same model and style.
Chapter 2: Hardware Information