INDOOR UNIT INSTALLATION
Wall hang
bracke t
Screw hole
● Next, check the drainage of the unit by pouring some water into the unit drain pan and ensure that the water drains out through the drain hose
and that there is no leakage from the other parts.
● After installation, if there is a significant gap between the unit and wall, it can be adjusted by securing 2 screws to the body and wall hang bracket.
Refer to the screw hole location(A, B) in Figure 12.
● Removing the frame grille ; ① Detach terminal block cover by removing two screws and remove two screws from frame grille.
26
Hook
② Pull the triangle marks located at the bottom of the frame grille and lift frame grille to the top of the unit.
● The recommended bending of the
drain hose is shown in Figure 13.
Note
Figure 13
Figure 12