Displaying The Egt Difference; Scanning Through The Channels Automatically; Normalized Operating Mode - Electronics International UBG-16 Operating Instructions Manual

Ultimate bar graph engine analyzer
Table of Contents

Advertisement

6. Displaying the EGT Difference:

6. Displaying the EGT Difference:
6. Displaying the EGT Difference:
6. Displaying the EGT Difference:
6. Displaying the EGT Difference:
While the Peak EGT is being displayed, push the Step Switch once to the right to
display the difference between the hottest and coldest EGT. A programmable limit may
be set to alert you when the EGT Differential Limit is exceeded (see "Programming the
EGT Differential Limit").

Scanning Through the Channels Automatically:

Scanning Through the Channels Automatically:
Scanning Through the Channels Automatically:
Scanning Through the Channels Automatically:
Scanning Through the Channels Automatically:
When operating in the Normal or Normalized Operating Mode, by pushing
and holding the step switch to the right until the word "SCAN" appears in the
digital display, you may set the UBG to automatically scan the digital display
through the various temperatures and/or functions being monitored. The
length of time a temperature or function will be displayed is programmable.
To cancel the Scan operation, push the step switch to the right or left, or push
the Mode Switch to the right.
If a limit is violated while operating in the Scan Mode, the scan will stop
and the UBG will display the channel with the violation.
When operating in the Scan Mode only
grammed by performing the following steps:
1. 1. 1. 1. 1. Push and hold the Mode Switch to the left until the word "PROGRAM" appears in the digital display.
When the Mode Switch is released, the word "SCAN R. X" will appear in the digital display. The number
blinking (X) in the right portion of the digital display is the Scan Rate in seconds.
2 2 2 2 2 . Push the Step Switch right or left to increase or decrease the Scan Rate.
3 3 3 3 3 . To exit this programming mode, push and hold the Mode Switch to the left until the word "END" ap-
pears in the digital display.

Normalized Operating Mode:

Normalized Operating Mode:
Normalized Operating Mode:
Normalized Operating Mode:
Normalized Operating Mode:
The purpose of the Normalized Operating Mode is to be able to compare
current engine operation to prior engine operation.
Once the height of the EGT columns has been normalized (brought to the
same level), any abnormal change in the engine's EGTs will show up as an
abnormally high or low column of bars. In this way you can see temperature
trends over weeks, months or years. The Bar Graph Display provides a
graph of long-term trend, allowing you to spot problems easily.
Scan Mode only
Scan Mode only, the Scan Rate may be pro-
Scan Mode only
Scan Mode only
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents