Note: Setting a limit to "000" will disable the limit and any alarms.
Note:
6. 6. 6. 6. 6. To exit this programming mode, push and hold the Mode Switch to the left until the word "END" appears
in the digital display.
Programming the High and Low Limits for Other Temperatures or
Programming the High and Low Limits for Other Temperatures or
Programming the High and Low Limits for Other Temperatures or
Programming the High and Low Limits for Other Temperatures or
Programming the High and Low Limits for Other Temperatures or
Functions:
Functions:
Functions:
Functions:
Functions:
It is recommended that high and low limits be set just outside the normal operating range for your engine so
problems can be detected without causing a false warning. False warnings are annoying and can desensitize you
to warnings in general. This could cause a serious delay in taking note of a warning which is an alert to a real
problem.
A High and Low Limit may be set for any temperature or function displayed on the UBG. When operating in the
Normal Mode only
Normal Mode only
Normal Mode only, the High and Low Limits may be set by performing the following steps:
Normal Mode only
Normal Mode only
1. 1. 1. 1. 1. Select the temperature or function on the digital display.
2. 2. 2. 2. 2. Press and hold the mode switch to the left until the word "PROGRAM" appears in the digital display.
Release the Mode Switch. "SET H" will appear on the left side of the UBG display. Also, the High Limit
will appear in the right portion of the digital display and the digit
to the far left will be blinking.
3. 3. 3. 3. 3. Use the Step Switch to increase or decrease the digit that is
blinking. The limits are set as shown in the chart following this
section.
4. 4. 4. 4. 4. Use the Mode Switch to blink a specific digit.
5. 5. 5. 5. 5. To display the Low Limit, push the Mode Switch to the right
until "SET L" appears on the left side of the UBG display.
Note: Setting a limit to "000" will disable the limit and any alarms.
Note:
Note:
Note:
Note:
6. 6. 6. 6. 6. To exit this programming mode, push and hold the Mode Switch to the left until the word "END" ap-
pears in the digital display.
16