These instructions are valid exclusively for countries the identification symbols of which appear on the cover of the instruction booklet and the label on the appliance. The manufacturer cannot be considered responsible for any damages to people or to things in the event of incorrect installation or improper use of the appliance.
Page 3
Attention: this appliance has been manufactured for domestic use only and it employment by private person.
Page 4
Attention: this appliance has been manufactured for domestic use only and it employment by private person.
Page 5
- Manual ignition - Automatic electric ignition - Lighting burners fitted with a safety cut-off device How to use the burners Stand the pan on the burner before lighting.
Page 6
WARNINGS AND RECOMMENDATIONS FOR Ø THE USER: Burners Power (W) Pan cm ●use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig.
Page 7
IMPORTANT: WARNINGS: always disconnect the appliance from the gas comply with the following instructions, before and electricity mains before carrying out any remounting the parts: cleaning operation. ●check that burner head slots “T” (fig. 8) have not become clogged by foreign bodies. ●Check that enamelled burner cap “A”,“B”,“C”...
TECHNICAL INFORMATION FOR THE INSTALLER Installation, adjustments of controls and maintenance must only be carried out by a qualified engineer (law n° 46 and D.P.R. 447). The appliance must be correctly installed in conformity with current law and the manufacturer's instructions. Incorrect installation may cause damage to persons, animals or property for which the Manufacturer shall not be considered...
IMPORTANT INSTALLATION INSTRUCTIONS The installer should note that the appliance that side walls should be no higher than the hot plate itself. Furthermore, the rear wall, the surfaces surrounding and adjacent to the appliance must be able to withstand a Before connecting the appliance, check that the temperature of 90 °C.
Page 10
IMPORTANT! The appliance must be installed following the manufacturer's instructions. manufacturer will not be liable for injury to persons or animals or property damage Before performing any service on the electrical caused by an incorrect installation. part of the appliance, it must absolutely be disconnected from the electrical network.
Page 11
Before performing any regulation, disconnect the electricity supply to the appliance. After carrying out any regulation or pre- regulation operations, any seals must be replaced by the technician. The regulation of primary air to our burners is not necessary. Regulation of the “Minimum”: After making these replacements, the technician must regulate the burners as described in paragraph 9, seal any regulation...
Page 12
*In accordance with Regulation No. 66/2014 EU measures for the implementation of Directive2009/125/EC, the performance (EEgas burner) was calculated according to EN 30-2-1 last review with the G20. **Mount with bushing (B) if present (see Fig. 14).
Page 13
*In accordance with Regulation No. 66/2014 EU measures for the implementation of Directive2009/125/EC, the performance (EEgas burner) was calculated according to EN 30-2-1 last review with the G20. **Mount with bushing (B) if present (see Fig. 14).
Page 14
CAUTION!!! When replacing the power cable, the fitter must keep the earth conductor “B” longer than the phase conductor (fig. 15) and must also observe the warnings indicated in paragraph 8. WARNING: MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED PERSONS. In case of failure or cut in the cable, please move away from the cable and do not touch it.