Troubleshooting; General Symptoms - Daikin EKHBX008BB3V3S Installation Manual

Indoor unit for air to water heat pump system
Table of Contents

Advertisement

A
PPENDIX
(for restricted power supply condition mode only)
First
Second
code
code
Setting name
d
Restricted power supply condition mode/local shift value weather dependent
00
Not applicable. Do not change the default value.
01
Not applicable. Do not change the default value.
02
Restricted power supply condition mode
03
Local shift value weather dependent
04
Not applicable.
05
Pump operation forced off or permitted during
backup heater is forced off at benefit kWh rate
power supply ([d-00]=0 or 1)
06
Not applicable.
E
Unit information readout
00
Software version
01
EEPROM version
02
Unit model identification. Do not change the default
value.
03
Liquid refrigerant temperature
04
Inlet water temperature
F
Option setup
00
Pump operation stop
01
Space cooling permission temperature
02
Bottom plate heater ON temperature
03
Bottom plate heater hysteresis
04
Functionality of X14A
Underfloor heating screed dry-out program
05
Action number selection
06
Heating set point of selected action number [F-05]
07
Time of selected action number [F-05]
08
Underfloor heating screed dry-out program enabled/
disabled
09
Latest action number executed
(a) Only possible to modify the first 3 minutes after power ON.
(b) For all action numbers of [F-05].
11. T
ROUBLESHOOTING

11.2. General symptoms

Symptom 10: Unexpected backup heater operation
P
OSSIBLE CAUSES
Entering water temperature is too
low and leaving water temperature
>25°C.
Too frequent use of the backup
heater during heating operation or
domestic water heating.
Installation manual
57
(a)
.
C
ORRECTIVE ACTION
Increase the water flow.
The water volume in the cicuit is too
low.
Installer setting at variance with default value
Date
Value
Date
Default
Value
value
Range
0
0/1/2/3
0 (OFF)
0/1/2
0 (OFF)
0/1
0 (OFF)
0/1/2/3/4
0 (forced
0/1
off)
Read only
Read only
depending
on model
Read only
Read only
0
0/1
(enabled)
20
10~35
3
3~10
5
2~5
1
0/1
1
1~20
(b)
25.0
15~55
(b)
0
0~72
0 (OFF)
0/1
0~21
0
(Read only)
Indoor unit for air to water heat pump system
Step
Unit
1
1
1
1
1
°C
1
°C
1
1
°C
1
°C
1
°C
1
1
°C
12
hour
1
0
EKHBX008BB3V3S
4PW62597-1 – 10.2010