Centering Magnet Adjustment
O
1. Preliminary steps
1) Receive the EU 05 CH signal.(PR.1 : PAL B/G 175.25MHZ)
2) Press the keys of Remote Controller for adjustment to reset the
convergence.
a.Adjustment mode:Press the IN-START key.
b.Data reset : Press 0 KEY.
c.Adjustment mode cancellation : Press the ENTER key.
2. Adjustment
1) Operate adjustment about Red,Green,Blue centering
magnet.
2) SGS-THOMSON Convergence assy
Adjust until the center of blue signal is shifted up to 40mm
left from that of green signal and center of red signal is
shifted up to 40mm right from that of green signal with
turning the centering magnet.
3) After adjustment, re-adjust convergence data and exit the
adjusting mode.
a.Adjustment mode:Press the IN_START key.
b.Data reset : Press 0 KEY.
c.Adjustment mode cancellation : Press the Enter key.
High Voltage Regulation Adjustment
O
1. Test Equipment
Digital Multi-Meter(DMM)
2. Preparation for Adjustment.
Select picture mode to 'DYNAMIC' in no signal input.
3. Adjustment
1) Press the IN_START key and then press '1' key.(HV ADS)
2) Connect "+" terminal(Red) of DMM to the P415 of the
Deflection PCB, [+] and the "-"terminal(Black) to the P416,[-].
3) Adjust VR401 so that the voltage of multimeter to be below
voltage.
Voltage: 21.7 ! 0.1V.
4) Exit the adjustment mode by pressing the enter key
CUT-OFF Voltage Adjustment
O
1. Preliminary steps
(1) Select INSTART key on the Remote Control and then
select "2 SCREEN ADJ" move the cursor or using the key
No..
2 Pole Magnet
4 Pole Magnet
6 Pole Magnet
(2) Adjustment must be operated in a dark room (simple dark
room)
2. Adjustment
(1) Test Equipment: Oscilloscope, 100:1 Probe
(2) Connect oscilloscope to cathode of R, G, B(R926R/B/G:
SCREEN ADJ on the PCB) and GND.
(3) Turning Screen Volume (R/G/B) in Focus Pack and adjust
R/G/B is 165V!0.5V.
0V
(4) After adjustment complete, exit the RASTER adjustment
mode using ENTER key and exit the SVC adjustment mode
using INSTART key.

Deflection Adjustment

O
1. Preliminary steps
1) NTSC mode should be adjusted after adjusting PAL mode.
2) NTSC adjustment should be done in STANDARD mode of
picture after receiving 13CH signal or MULTI 48CH
signal,and PAL adjustment should be done in STANDARD
mode of picture after receiving EU05 CH.
3) Reset the data in convergence adjustment mode,quit the
mode.
Adjustment Mode : Press the IN_START key and then '0'
key.
Data reset : Press the "0" key.
Adjustment mode cancellation :Press the ENTER key.
4) Display only the Green raster using lens covers to block Red
and Blue.
2. PAL Mode Deflection adjustment
Do not adjust V-LIN, S-COR, A-BOW, A-ANG, UCPIN, LCPIN,
V-ASP, V-SCR in PAL MODE. At SVC mode, press the '0'
key get into the deflection adjustment mode.
1) VS (Vertical Shift)
Adjust until the geometric vertical center line is accord with
the vertical center line of screen JIG in EU 05 CH by
pressing the VOLUME
2) VA (Vertical Amplitude)
Adjust until sixth vertical line from upper and lower center of
the screen is accord with the last point of the frame.
3) HS (Horizontal Shift)
Adjust until the geometric horizontal center line is accord with
the horizontal center line of screen JIG.
4) EW (East-west Width)
Adjust until the outermost left and right vertical line of the
screen is accord with the last point of the frame.
5) EP (East-west Parabola)
Adjust so that middle portion of the outermost left and right
vertical line looks like parallel with vertical lines of the PRT.