Summary of Contents for MuxLab 500444

  • Page 1 HDMI 4x4 Matrix Switch, 4K/60 Operation Manual 500444 © Muxlab Inc. 2017 94-000855-A / SE-000855-A...
  • Page 2: Safety Precautions

     Unplug the power when left unused for a long period of time.  Information on disposal of devices: do not burn or mix with general household waste, please treat them as normal electrical waste. NOTICE: Please read this manual carefully before using this product. © Muxlab Inc. 2017...
  • Page 3: Table Of Contents

    6.4 Menu – View IP Config ..................13 6.5 Connectivity Operation ..................14 7. IR Handheld Remote Control ..................15 8. RS232 Remote Control ....................16 9. Telnet Remote Control ....................19 Regulatory Compliance ....................20 © Muxlab Inc. 2017...
  • Page 4: Introduction

    Operation Manual 1. Introduction The HDMI 4x4 Matrix Switch, 4K/60 (500444) connects four HDMI sources to four displays. The matrix supports 1080p @ 60Hz up to 4K @ 60Hz (4:4:4), 3D formats and EDID management. It works with Blu-Ray players, Set-Top Boxes, Media Players, Home Theater PCs, and Game Consoles that connect to an HDMI display.
  • Page 5: Features

     One (1) Handheld IR Remote  Two (2) Mounting ears  One (1) IR Sensor cable Note:Please confirm if the product and the accessories are all included. If not, please contact the location at which you purchased the unit. © Muxlab Inc. 2017...
  • Page 6: Specifications

    Humidity: Up to 95% non-condensing Power Consumption 33W (max) Compliance Regulatory: FCC, CE, RoHS Warranty 2 Years Ordering Information 500444-US HDMI 4x4 Matrix Switch, 4K/60, US 500444-UK HDMI 4x4 Matrix Switch, 4K/60, UK 500444-EU HDMI 4x4 Matrix Switch, 4K/60, EU © Muxlab Inc. 2017...
  • Page 7: Panels Description And Unit Installation

    EDID info and so on. Ethernet: This port is the link for TCP/IP control. Connect to an active Ethernet link with an RJ45 terminated Ethernet cable. RS232: Connect to a PC running terminal emulation or © Muxlab Inc. 2017...
  • Page 8: Matrix Switch Installation

    HDMI Connect HDMI sources. Input HDMI Output for HDMI displays, AVR, etc. Output 5.3 Matrix Switch Installation Mount the Matrix Switch in its final location, such as on a 19 rack, with the supplied mounting brackets. © Muxlab Inc. 2017...
  • Page 9: Management Options

    See the “Local Switch Control” chapter for managing the unit via the front panel. Refer to the Handheld Remote Control chapter to manage the Matrix Switch via the supplied Handheld IR Remote. See the RS232 Control chapter to manage the unit remotely via RS232. © Muxlab Inc. 2017...
  • Page 10: Front Panel Control

    ALL) to apply the scaling, and press [Enter] to set it. Each output port can have its own scaling setting, independent of any other output. The “Set Out Scaler” menu supports the following options: 1 Bypass No scaling 2 Auto Set to auto scaling © Muxlab Inc. 2017...
  • Page 11: Menu - Select Edid Per Port

    4K/30Hz, 3D, 6CH Audio 4K/30Hz, 3D, 8CH Audio 4K/60Hz (Y420), 3D, 2CH (PCM) Audio 4K/60Hz (Y420), 3D, 6CH Audio 4K/60Hz (Y420), 3D, 8CH Audio 4K/60Hz, 3D, 2CH (PCM) Audio 4K/60Hz, 3D, 6CH Audio 4K/60Hz, 3D, 8CH Audio © Muxlab Inc. 2017...
  • Page 12 The source can then configure its output to send only resolutions and features that are compatible with the attached device/display. This information is called EDID (Extended Display Information Data). Also, a source device can only accept and read one EDID from a © Muxlab Inc. 2017...
  • Page 13: Menu - View Ip Config

    The “View IP Config” menu has the following IP parameters to view: 1 IP Address Show the Matrix Switch IP Address (default IP address is: 192.168.001.239) 2 TCP Port & Shows the TCP Port Number, and the DHCP © Muxlab Inc. 2017...
  • Page 14: Connectivity Operation

    When making a connection, begin by pressing the Output port (1 to 4, or ALL), then press the Input port (1 to 4, or ALL) to be connected. Note: An Input port may be connected to more than one output port. © Muxlab Inc. 2017...
  • Page 15: Ir Handheld Remote Control

    IR Handheld Remote. However an IR Sensor may also be connected to the IR Ext port on the rear of the unit, in order to extend the IR sensor to a more convenient location for improving line-of-site with the IR handheld remote. © Muxlab Inc. 2017...
  • Page 16: Rs232 Remote Control

    The Matrix Switch may be managed via RS232 commands. Connect an RS232 cable between the command terminal (which may be a PC running terminal emulation software) and the Matrix Switch. MuxLab also provides at no charge a control software package that may be downloaded from the MuxLab website, to be used to send RS232 commands to the Matrix Switch.
  • Page 17 11:4K60HZ(Y420)_3D_8CH 12:4K60HZ_3D_2CH 13:4K60HZ_3D_6CH 14:13:4K60HZ_3D_8CH 15:1080P_2CH(HDR) 16:1080P_6CH(HDR) 17:1080P_8CH(HDR) 18:1080P_3D_2CH(HDR) 19:1080P_3D_6CH)(HDR) 20:1080P_3D_8CH(HDR) 21:4K30HZ_3D_2CH(HDR) 22:4K30HZ_3D_6CH(HDR) 23:4K30HZ_3D_8CH(HDR) 24:4K60HZ(Y420)_3D_2CH(HDR) 25:4K60HZ(Y420)_3D_6CH(HDR) 26:4K60HZ(Y420)_3D_8CH(HDR) 27:4K60HZ_3D_2CH(HDR) 28:4K60HZ_3D_6CH(HDR) 29:13:4K60HZ_3D_8CH(HDR) 30:USER1_EDID 31:USER2_EDID 32:USER3_EDID SET INx EDID CY OUTy Copy Output y EDID To Input x(USER1 BUF){x=[0~4](0=ALL), y=[1~4]} © Muxlab Inc. 2017...
  • Page 18 SET DHCP y Set DHCP {y=[0~1](0=Dis,1=Enable)} GET RIP Get Route IP Address GET HIP Get Host IP Address GET NMK Get Net Mask GET TIP Get TCP/IP Port GET DHCP Get DHCP Status GET MAC Get MAC Address © Muxlab Inc. 2017...
  • Page 19: Telnet Remote Control

    The RS232 commands in the previous section, may also be used via Telnet, allowing the Matrix Switch to be managed over a TCP/IP network. Open a Telnet session, use port 23, and make use of the RS232 commands above. © Muxlab Inc. 2017...
  • Page 20: Regulatory Compliance

    All brand names and product names used in this document are trademarks, or registered trademarks of their respective holders. 8495 Dalton Road, Mount Royal, Quebec, Canada. H4T 1V5 Tel: (514) 905-0588 Fax: (514) 905-0589 Toll Free (North America): (877) 689-5228 E-mail: videoease@muxlab.com URL: www.muxlab.com © Muxlab Inc. 2017...