EPIRB Test Report Generator

The "EPIRB" tab offers two options:
1. Generation of complete EPIRB test reports out of test results from the test box,
2. PC-controlled EPIRB testing and simultaneous generation of test reports.
1. Generating reports out of stored test results
This window allows you to generate complete EPIRB test reports out of the test results stored in
the test box.
1) Select the EPIRB test from the list at the right hand side. If there is no list,
go to the "Test results" tab and select from the Index a header that contains the
relevant EPIRB test. Then return to the "EPIRB" tab.
2) Fill in the beacon information form in the EPIRB dialogue box at the left hand side.
3) Press "Generate Report" to create the EPIRB Test Report (HTML format).
See example of an EPIRB Test report on the next page.
During the installation of the Test Box Manager PC software, a default report template has been
placed in C:\EPIRB\ on your PC. Feel free to use this HTML document as the basis for creating
your own layout or design, if so wished. Then, press "Get template" and select the new one
from your file system instead of the default template.
Please note: Default limits of the frequency tolerance and minimum signal level are +/- 5 kHz
and 190 respectively. Other limits may be inserted in accordance with specifications. Should the
limits be exceeded during test, the report will write "Failed" in the status line.