Philips MCP9360i Service Manual page 38

Mediacenter pc
Hide thumbs Also See for MCP9360i:
Table of Contents

Advertisement

EN 38
11.
11.27. IR Blaster
11.27.1. Required Equipment
Two IR blaster cables
Test CD
11.27.2. Test Procedure
1.
Insert the two IR blaster cables in the rear IR blaster ports.
2.
Hold the 'eyes' of the cables in front of the IR receiver in the front of the set (to the left of the VFD display).
3.
Open a command window. (Select: Start > Run . Type ' cmd ' and click OK ).
4.
In the command window: find and run the program ' IR.bat '.
5.
Check if both cables pass the test. If not, move the 'eyes' a bit and try again until absolutely sure that there is a hardware failure.
11.27.3. Fail Procedure
Replace the motherboard. See paragraph 12.15.9.