Installation And Initial Checks - Philips MCP9360i Service Manual

Mediacenter pc
Hide thumbs Also See for MCP9360i:
Table of Contents

Advertisement

7.

Installation and Initial Checks

7.1.
Installation
1.
Connect the MCP9360i to a monitor, using either the DVI or the VGA connector.
2.
Insert the power cord (both 110V or 230V are supported). The LED on the Standby-On button should light-up yellow.
3.
Connect a USB keyboard to one of the front USB ports.
7.2.
BIOS Check
7.2.1.
Test Procedure
1.
Install the MCP9360i. See paragraph 7.1.
2.
Press the Standby-On button. The LED on the Standby-On button will turn-off and the MCP9360i should begin to start up.
3.
During the early part of the start-up process press the 'F2' key on the keyboard to enter the BIOS setup.
4.
On the BIOS setup main screen check the installed memory size. See table below.
Total memory size
5.
Check the system manufacturer information. (BIOS menu select: Main > Additional system information ). See table below.
System information > manufacturer
Desktop board information > manufacturer
Chassis Information > Manufacturer
6.
Check the BIOS version. (BIOS menu select: Main > BIOS version ). See table below.
Software module
System BIOS
7.
Check that the HDD and the optical drive have been detected by the BIOS. (BIOS menu select: Advanced > Drive
Configuration ). See table below.
Drive
HDD (primary supplier)
Optical Drive
Check the function of the temperature sensors. Confirm that the temperatures have reasonable values, between 0 °C and 128 °C.
8.
(BIOS menu select: Advanced > Hardware Monitoring ). See table below.
Temperature Sensor
Processor 1
Front internal
Rear internal
Remote 1
Remote 2
9.
Check the fan speeds. (BIOS menu select: Advanced > Hardware Monitoring ). See table below.
Fan
Processor 1 fan
Rear fan
Installation and Initial Checks
1024 MB
"Tatung co."
Intel Corporation
Philips MCPC1001
Release version
SU94510J.86A.0044.2005.0727.0111
Type
Western Digital WD1600JS-55M-250.0GB
Philips DVDR1628 – ATAPI
Possible value (allow for a wide variation)
63 °C
31 °C
25 °C
23 °C
21 °C
Speed (allow for a wide variation)
900 – 1400 RPM
1000 RPM
MCP9360i
7.
EN 13

Advertisement

Table of Contents
loading

Table of Contents