JVC LT-37M60BU Service Manual page 63

Wide lcd panel television
Hide thumbs Also See for LT-37M60BU:
Table of Contents

Advertisement

www.freeservicemanuals.info
LT-37M60BU, LT-37M60BU/P,
LT-37M60ZU, LT-37M60ZU/P
STANDARD CIRCUIT DIAGRAM
NOTE ON USING CIRCUIT DIAGRAMS
1.SAFETY
The components identified by the
critical for safety. For continued safety replace safety ciritical
components only with manufactures recommended parts.
2.SPECIFIED VOLTAGE AND WAVEFORM VALUES
The voltage and waveform values have been measured under the
following conditions.
(1)Input signal
(2)Setting positions of
each knob/button and
variable resistor
(3)Internal resistance of tester
(4)Oscilloscope sweeping time
(5)Voltage values
Since the voltage values of signal circuit vary to some extent
according to adjustments, use them as reference values.
3.INDICATION OF PARTS SYMBOL [EXAMPLE]
In the PW board
4.INDICATIONS ON THE CIRCUIT DIAGRAM
(1)Resistors
Resistance value
No unit
K
M
Rated allowable power
No indication
Others
Type
No indication
OMR
MFR
MPR
UNFR
FR
Composition resistor 1/2 [W] is specified as 1/2S or Comp.
(2)Capacitors
Capacitance value
1 or higher
less than 1
Withstand voltage
No indication
Others
AC indicated
Electrolytic Capacitors
47/50[Example]: Capacitance value [µF]/withstand voltage[V]
symbol and shading are
: Colour bar signal
: Original setting position
when shipped
: DC 20kΩ/V
: H
20µs / div
: V
5ms / div
: Othters
Sweeping time is
specified
: All DC voltage values
: R209
R209
: [Ω]
: [kΩ]
: [MΩ]
: 1/16 [W]
: As specified
: Carbon resistor
: Oxide metal film resistor
: Metal film resistor
: Metal plate resistor
: Uninflammable resistor
: Fusible resistor
: [pF]
: [µF]
: DC50[V]
: DC withstand voltage [V]
: AC withstand voltage [V]
Digitized in Heiloo Netherland
Type
No indication
: Ceramic capacitor
MM
: Metalized mylar capacitor
PP
: Polypropylene capacitor
MPP
: Metalized polypropylene capacitor
MF
: Metalized film capacitor
TF
: Thin film capacitor
BP
: Bipolar electrolytic capacitor
TAN
: Tantalum capacitor
(3)Coils
: [ µ H]
No unit
Others
: As specified
(4)Power Supply
: B1
: 9V
Respective voltage values are indicated
(5)Test point
: Test point
(6)Connecting method
: Connector
: Receptacle
(7)Ground symbol
: LIVE side ground
: ISOLATED ( NEUTRAL ) side ground
: EARTH ground
: DIGITAL ground
5.NOTE FOR REPAIRING SERVICE
This model's power circuit is partly different in the GND. The
difference of the GND is shown by the LIVE : (
ISOLATED ( NEUTRAL ) : (
) side GND. Therefore, care must be
taken for the following points.
(1)Do not touch the LIVE side GND or the LIVE side GND and the
ISOLATED ( NEUTRAL ) side GND simultaneously. if the above
caution is not respected, an electric shock may be caused.
Therefore, make sure that the power cord is surely removed from
the receptacle when, for example, the chassis is pulled out.
(2)Do not short between the LIVE side GND and ISOLATED ( NEUTRAL )
side GND or never measure with a measuring apparatus measure
with a measuring apparatus ( oscilloscope, etc.) the LIVE side GND
and ISOLATED ( NEUTRAL ) side GND at the same time.
If the above precaution is not respected, a fuse or any parts will be broken.
Since the circuit diagram is a standard one, the circuit and
circuit constants may be subject to change for improvement
without any notice.
NOTE
Due improvement in performance, some part numbers show
in the circuit diagram may not agree with those indicated in
the part list.
When ordering parts, please use the numbers that appear
in the Parts List.
4/19/2017
: B2 ( 12V )
: 5V
: Only test point display
: Wrapping or soldering
) side GND and the