Problem
Picture is green on
INPUT 1 (Component)/
INPUT 2 (Component).
Picture is pink (no green)
on INPUT 1 (RGB)/INPUT
2 (RGB).
Picture flickers on INPUT
1 (RGB)/INPUT 2 (RGB).
ter Compatibility Chart
Picture is too bright and
nal support
whitish.
requency: 15-70 kHz,
The cooling fan becomes
quency: 45-85 Hz,
noisy.
12-108 MHz
The lamp does not light
: Compatible with TTL level
up even after the
with sync on green signal
projector turns on.
is a list of modes that conform to VESA. However, this projector supports other
The lamp suddenly turns
e not VESA standards.
off during projection.
The image sometimes
Horizontal Frequency
Resolution
(kHz)
flickers.
27.0
640 × 350
31.5
37.5
27.0
640 × 400
31.5
The lamp needs much
37.9
27.0
time to turn on.
720 × 350
, 2 and COMPUTER-RGB/COMPONENT OUTPUT Terminals:
31.5
A
Picture is dark.
27.0
720 × 400
31.5
B Input/Output
37.9
This unit is equipped with a microprocessor. Its performance could be adversely affected by incorrect operation
26.2
(red)
or interference. If this should happen, unplug the Unit and plug it in again after more than 5 minutes.
31.5
(green/sync on green)
34.7
640 × 480
(blue)
37.9
37.5
ed
43.3
ed
31.4
35.1
37.9
/sync on green)
800 × 600
GA
46.6
48.1
ed
46.9
53.7
40.3
ed
48.4
al data
1,024 × 768
A
56.5
ync signal: TTL level
60.0
68.7
c signal: TTL level
55.0
1,152 × 864
66.2
GA
67.5
onnector
1,280 × 1,024
64.0
1,400 × 1,050
A+
64.0
640 × 480
Name
I/O
A
34.9
800 × 600
37.8
GA
832 × 624
49.7
Receive Data
Input
1,024 × 768
A
60.2
Send Data
Output
1,152 × 870
GA
68.7
Lamp unit
Signal Ground
AN-100LP
Request to Send
jector receives 640K350 VESA format VGA signals, "640K400" appears on the screen.
Clear to Send
ector of the DIN-D-sub RS-232C adaptor (optional
tion
Downloaded from ProjectorsManual.com Manuals
Name
I/O
Horizontal Frequency (kHz)
ector to
15.7
NDBY/ON button
Receive Data
Input
• Change the input signal type setting.
Select "Color is faded or poor" in the "Help" menu, and then select
an input signal type.
• Select "Initiate "Auto Sync" Adjustments" after selecting "Vertical
stripes or flickering image appear" in the "Help" menu, and then
press ENTER.
If the picture hasn't improved, select "Adjust horizontal noise", and
then press ENTER. After that, press O or Q to adjust.
• Image adjustments are incorrectly set.
• Compatible with the signals below in
intelligent compression
• When temperature inside the projector increases, the cooling fan
SVGA, XGA, SXGA, SXGA+
runs faster.
• Intelligent Compression and Expansion
• The lamp indicator is illuminating in red.
System resizing technology
Replace the lamp.
• Cables incorrectly connected to the projector or the connected
Vertical Frequency
(Hz)
equipment works improperly.
60
• Select "Vertical stripes or flickering image appear" in the "Help"
70
menu and make the necessary adjustments.
85
• If this happens frequently, replace the lamp.
60
70
• The lamp will eventually need to be changed.
85
60
While the remaining lamp life draws to a close, replace the lamp.
70
60
70
Component Input/Output
85
50
1.
PR (CR)
60
2.
Y
70
3.
PB (CB)
72
75
4.
Not connected
85
5.
Not connected
50
6.
Earth (PR)
56
60
7.
Earth (Y)
70
8.
Earth (PB)
72
9.
Not connected
75
10. Not connected
85
50
11. Not connected
60
12. Not connected
70
13. Not connected
75
85
14. Not connected
60
15. Not connected
70
75
60
60
Reference
67
60
Not connected
75
Connected to internal circuit
75
Connected to internal circuit
75
Not connected
Connected to internal circuit
Not connected
Connected to CS in internal circuit
Connected to RS in internal circuit
Not connected
Reference
Vertical Frequency (Hz)
Not connected
60
Connected to internal circuit
Check
VESA Standard
Display
Upscale
Intelligent Compression
Upscale
Intelligent Compression
Page
46
46
42
48, 51
23–27
46
51
51
5