EMC Performance

Safety Specifications

Power Supply Protection

Repair Specifications

56 Specifications
EMC performance can be further enhanced with the following accessories:
Backplane Connector Shields per VXI rev 1.4, B.7.2.3.
1-slot Blank Panel with EMI Contact per VXI rev 1.4, B.7.2.3
Intermodule Chassis Shield per VXI rev 1.4, B.7.3.4
IEC 61010-1 (1990) including Amendments 1 (1992) and 2 (1995)
EN 61010-1 (1993) including Amendment 2 (1995)
CSA C22.2 #1010.1 (1992)
UL 3111-1 (1994)
All outputs protected from over-temperature, over-voltage, over-current,
short-to-ground and short-to-other-output. Protection mode is full
shutdown. Recovery occurs when the fault condition is removed and power
on/standby is cycled.
Diagnosis and Troubleshooting through the front panel monitor and
connector.
MTTR for Power Supply:<5 min (with mainframe and modules fully
installed in rack)
MTTR for Impeller and/or Fan:<5 min (with mainframe and modules fully
installed in rack)