Replacing TX-RX Unit

■ TX-RX unit Information

Original TX-RX
Model Name
unit Number
NX-210 (K2: 18-key)
X57-7710-10
■ Method of confi rming "Original TX-RX unit" and
"Service TX-RX unit"
X57-771
Component side
The 0Ω resistor (R963) is mounted
on the "0-11" silk print part of the
Service TX-RX unit (X57-7710-11).
X57-771
R962
0-10
0-11
(None)
Note:
• The 0Ω resistor (R962 and R963) is used to differenti-
ate the destination with a visual check. These are not
connected with any PCB pattern; they are specifically
for production control. There is no need to change the
mount of two resistors.
• There is no difference between the schematic diagram
of the Service TX-RX unit (X57-7710-11) and the sche-
matic diagram of the original TX-RX unit (X57-7710-10).
(R962 and R963 are connected with GND (ground) only.)
TROUBLE SHOOTING
For Service TX-RX
unit Number
X57-7710-11
R962
R963
R963
(None)
■ Supplied Accessories of "Service TX-RX unit"
Item (Including Parts Number)
NX-210 TX-RX Unit (X57-771)
Kenwood ESN Label
NXDN ESN Label
Addendum (B59-2586-XX)
■ "Service TX-RX unit" Data
The following data is written on the service TX-RX unit:
Data Type
Firmware
NX-200/210/300 Firmware.
FPU Data
X57-771 (NX-210) K2 type data.
(PC programming mode)
Various Adjustment Data
General adjustment values for the
(PC Test mode)
X57-771 (NX-210).
Model name: NX-210S
Type: K2
Kenwood ESN
The same number as the Kenwood
ESN label is written.
The same number as the NXDN ESN
NXDN ESN
label is written.
■ After Changing the PCB
1. After changing the printed circuit board, write the up-
to-date Firmware following the instructions in the "RE-
ALIGNMENT - 6.Firmware Programming Mode".
2. Using the KPG-111D, select your desired item (Model
Name and Frequency) from the Model> Product Informa-
tion menu, then use Program> Write Data to the Trans-
ceiver to write the FPU data (PC Programming mode).
When writing to the transceiver, a Warning Message,
corresponding to the item selected, appears. Click [OK]
to continue writing the data.
3. Enter Program> Test Mode, then adjust the various ad-
justment data (PC Test Mode) as described in the "AD-
JUSTMENT".
4. Attach the new labels corresponding to the new printed
circuit board. (Refer to the images on page 36 for label
placement.)
5. If necessary, write the FPU data used by the customer
with the KPG-111D.
Note:
• When using the ESN Validation function of NXDN Trunk-
ing, the NXDN ESN number changes when the circuit
board is changed (the number is written on the circuit
board); the NXDN Trunking System cannot be accessed.
Use the KPG-110SM on the NXDN Trunking System side
to reprogram the NXDN ESN number.
• When a new printed circuit board is used, the Kenwood
ESN changes, as does the Transceiver Information dis-
play of the KPG-111D, but this does not have any effect
on the operation of the transceiver.
• If changing to the original Kenwood ESN and NXDN ESN,
please contact our service center.
NX-210