Table of Contents 1. Introduction............. Pg.16 2. Basic Information for Using the Central Station..Pg.16 2.1. Operation/ Function Elements....Pg.16 2.2. Installation..........Pg.16 2.2.1. Installing/Changing Batteries....Pg.17 2.2.2. Setting up the central Station..... Pg.17 2.2.3. Connenctions to a Layout....Pg.17 2.2.4.
It is best if you refrain from “expensive” experiments. The Central Station is not a toy. Make sure that this unit is used by children only as a controller for model trains. We hope and trust that you will have much enjoyment in the use of the Central Station on your model railroad layout.
- Do not remove the batteries until the Central Station is turned off. - If the Central Station is not going to be used for a long period of time, then the batteries should be removed. (to protect against the...
Mobile Stations can be connected to the Systems network by means of the 60125 Terminal. The connection socket for the Mobile Station on the rear of the Central Station can be selected from one of three brown alternatives. If additional Mobile Stations are connected to these free sockets, they will be free from damages.
3.2.2. Operating the Touch Screen track, etc.). Now plug the power cord for the Central Station’s trans- The Central Station has a Touch Screen (a screen that reacts to being former into the wall outlet. touched). By simply touching the screen above a symbol shown there, a desired action will be carried out.
3.3.2. Setting up Locomotives with Delta or Digital Decoders Pressing the “STOP” Button: The Central Station is also able to control the different Märklin Delta The electrical power for the layout and for the programming track is or Digital decoder generations, which are designed for operation with turned off.
Page 8
Example: The list is sorted by names. If you press on the key for “8”, new locomotive you are setting up in the Central Station. To do this, the class 80 will appear from the different data lines, since it is the touch the locomotive symbol depicted or the arrow positioned to first data line that begins with the number “8”.
Reverse operation: The forward and reverse direction of travel can decoder is returned to the factory default settings; in the be swapped on the locomotive. other situation the Central Station is returned to a defined starting condition. Vmax: Setting the maximum speed in the highest speed level.
Page 10
Two or more locomotive coupled together can also be controlled Note the direction of travel for the locomotive. Take the locomotive jointly with the Central Station. To do this, an entry is generated in the off of the layout. Change the direction of travel on the display. Set the...
first Please note: locomotive, regardless of what auxiliary functions these other units • Mfx locomotives must be in contact with the Central Station when may have. For that reason, you must select the models so there changing function buttons.
1. The decoder takes its data and power for the solenoid accessories connected to it from the track powered by the Central Station. 2. A ring circuit is set up from the Central Station for powering deco- ders. To do this, two 72090 distribution strips are inserted between...
After aspects is that the second solenoid must be connected to the you have confirmed the entry, the Central Station will not ask again if address directly after the address for the first decoder connection.
Central Station. 5. Turn the Central Station on. As soon as the Central Station is ready Note: Please have the hardware and software version numbers given to be operated, press the STOP button (emergency stop).
(control area with the check mark If the power supplied from the Central Station is not enough over in the lower right). time, then the layout must be divided up into areas of equal size in terms of the power consumed.
Need help?
Do you have a question about the Central Station and is the answer not in the manual?
Questions and answers