Depart. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.3
Battery Charging (IGN : Ignition) / Current consumption
8.3.1
Charger detection / Battery charging
- Plug the transformer unit into an easily accessible AC power socket.
- Insert the Test production Card in the mobile, plug a dummy Battery with a multimeter added (see picture) for
current measurement.
- Plug the connector of the charger (+4.2VDC 300mA max.) into the right socket at the base of the transceiver. The
battery symbol should indicate the state of charge :
•
Bars moving
•
Steady
If the battery is totally discharged, the battery icon will start scrolling 2 to 3 minutes only after being connected to
charger.
Just after charger plugging a pre-charge current 30 < I (mA) < 70 can be observed during 2 or 3 seconds
After few seconds a charge current of 300 mA approx. has to be observed
- Unplug the charger
PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
Service Repair Support
BAT -
- means the battery is being charged.
- means the battery is fully charged.
COMPANY RESTRICTED
VY-V-640-P330
Page : 20 of 43
Langue : EN
Date : 11/06/03
BAT +
VY-V-640-P330