  • Page 1 MAKING MODERN LIVING POSSIBLE FP715Si Electronic 2-Channel Full Programmer for Heating and Hot Water with Service Interval Timer Installation Guide Danfoss Heating...
  • Page 2 Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
  • Page 3: Table Of Contents

    FP715Si Electronic 2-Channel Full Programmer for Heating & Hot Water with Service Interval Timer Index 1.0 Installation Overview ................4 2.0 Product Specifi cation ................4 3.0 Installation 3.1 Wiring .....................5 3.2 DIL Switch Settings ................6 4.0 Advanced Programming Options .............6 5.0 Copy Functions Explained ..............7 6.0 Service Interval Timer ................9...
  • Page 4: Installation Overview

    • From the top left hand corner of the wallplate, there must be clearances of at least 140 mm to the right, 15mm to the left, 30mm above and 100mm below in order to mount the plug-on module. FP715SI...
  • Page 5: Wiring

    On 24 volt models power supply must be wired to N L 1 2 3 4 A & B on wallplate. 230V Fused Please Note: Always switch off mains fi rst and never fi t programmer to a live wallplate. Danfoss Heating...
  • Page 6: Dil Switch Settings

    2 on/off s each day Option 2 - (Disable or enable auto time change) Press NEXT, then use + or - to change between auto time change enabled to auto time change disabled. Auto time change enabled (Factory setting) Auto time change disabled FP715SI...
  • Page 7: Copy Functions Explained

    COPY button. The previously fl ashing day will stop fl ashing to indicate it has been de-selected. NOTE: When a day has been copied to, it will remain visible and not fl ashing when the DAY button is used to select other days. Danfoss Heating...
  • Page 8 1. Programme “A” day events using the + (time advance), - (time decrease), and NEXT (next period) buttons. 2. Press the DAY button to change to programme the “B” days. 3. Programme “B” day events using the + (time advance), - (time decrease), and NEXT (next period) buttons. FP715SI...
  • Page 9: Service Interval Timer

    The FP715 Si is fi tted with an installer setback service interval timer. If this feature is required please contact our technical department. Setting instructions for this gas safety feature are only available to bona fi de heating installers. Danfoss Heating...
  • Page 10: Wiring Conversions

    Table A MAINS DANFOSS RANDALL FP715, CP715 (PUMPED) DANFOSS RANDALL 922/972 DANFOSS RANDALL 4033 DANFOSS RANDALL SET 5 HORSTMANN 423, AMETHYST 7 & 10 HORSTMANN 424 GEM 1,10 HORSTMANN LEUCITE 423 & 424 HORSTMANN 425 DIADEM HORSTMANN 525 & 527 HONEYWELL ST669 HONEYWELL ST6300 &...
  • Page 11 This conversion applies nected leads (or pairs) go to LIVE only if..should be terminated Programmed selectors UNLINKED Terminals 5,8 & 10 are LINKED Terminals 5 & 7 are LINKED Programme selectors UNLINKED Programme selectors UNLINKED Programme selectors UNLINKED Danfoss Heating...
  • Page 12 Table A continued MAINS DANFOSS RANDALL FP715, CP715 (PUMPED) SANGAMO S409/3 SATCHWELL LIBRA & DHP 2201 SATCHWELL ET 1401 & 1451 SMITHS IND. CENTROLLER 90 SMITHS IND. CENTROLLER 1000 SWITCHMASTER 800 & 805 SWITCHMASTER 900 & 9000 SWITCHMASTER SONATA VENNER CHC/W2 (WITH STAT)
  • Page 13 NOTE where these discon- these terms This conversion applies nected leads (or pairs) go to LIVE only if..should be terminated Programme selectors UNLINKED Programme selectors UNLINKED Used in a system having independent control of water and heating Danfoss Heating...
  • Page 14 HORSTMANN 425 DIADEM HORSTMANN 525 & 527 HONEYWELL ST669 POTTERTON EP2000, EP3000 RANDALL TSR2P RANDALL MKII R6 DANFOSS RANDALL 3060 & 3020P RANDALL 701 DANFOSS RANDALL SET 2 SANGAMO M5 410 FORM 4 SANGAMO S409 FORMS 1 & 4 N,1,3...
  • Page 15 Programme selectors UNLINKED Programme selectors UNLINKED ...set for gravity HW Programme selectors UNLINKED 1 & 2 are LINKED 5 & 6 are LINKED With Links L-2 & 1-5 1 & 6 are LINKED 1 & 3 are LINKED Danfoss Heating...
  • Page 16 Table B cont... MAINS DANFOSS RANDALL FP715, CP715 (PUMPED) SMITHS IND. CENTROLLER 1000 SMITHS IND. CENTROLLER 60 SMITHS IND. CENTROLLER 10 SMITHS IND. CENTROLLER 70 SMITHS IND. CENTROLLER 1000 SWITCHMASTER 320 & 350 SWITCHMASTER 400 SWITCHMASTER 600 SWITCHMASTER 900 & 9000...
  • Page 17 LIVE applies only if..should be terminated Programme selectors UNLINKED L & 4 are LINKED Programme selectors UNLINKED A/S 5 Used in a system having A/S 3 control of WATER ONLY or WATER & HEATING TOGETHER A/S 5 Danfoss Heating...
  • Page 18 FP715SI...
  • Page 19 Danfoss Heating...
  • Page 20 Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 0845 1217 400 Fax: 0845 1217 515 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No. 38161v01s7-06 01/11...