  • Page 1 Operator’s Manual Danfoss Contamination Control Products FT1555-BM bench mount capping machine...
  • Page 2: Table Of Contents

    Installation / Environment ....................... 5 Machine operation ........................5 Maintenance instructions ......................8 Sizing chart heat seal capsules ....................10 CE declaration of conformity for machineru ...............11 Contact information .........................12 2 | © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. AQ445452814730en-000101...
  • Page 3: Capabilities

    Weight: 20.5 Pounds. (9kg). Cycle time: 2.0 seconds. Voltage: 230 Volt, single phase, 50/60 Hz, 15 Amps. Power consumption: 3,400 Watts. Heater temperature: 163°C / 325°F. Mark of conformity: AQ445452814730en-000101 © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. | 3...
  • Page 4: General Information

    This is not a field repairable machine. Do not open machine enclosure except to perform maintenance as outlined in this manual. 4 | © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. AQ445452814730en-000101...
  • Page 5: Installation / Environment

    Connect to an appropriate power source using a NEMA L6-15, 2-pole, 3-wire grounding, 15 Amp 230V locking plug and outlet. (See Figure 2) Figure 2 Figure 3 AQ445452814730en-000101 © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. | 5...
  • Page 6 Note: White indicator light will illuminate when heater is activated. Place CapSeal capsule over the end-fitting securely ensuring that the fitting is fully inserted into the capsule. (See Figure 7). Figure 5 Figure 7 6 | © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. AQ445452814730en-000101...
  • Page 7 (See Figure 10). about 3” and hold for at least 2 seconds. (See Figure 8 & 9). Figure 8 Figure 10 Figure 9 AQ445452814730en-000101 © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. | 7...
  • Page 8: Maintenance Instructions

    (See Figure 12). Figure 14 Figure 12 8 | © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. AQ445452814730en-000101...
  • Page 9 Remove the switch end plate and inspect the air intake grill for debris. Using a coarse brush remove any debris from the intake grill that could obstruct air flow. (See Figure 16). Figure 18 Figure 16 AQ445452814730en-000101 © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. | 9...
  • Page 10: Sizing Chart Heat Seal Capsules

    64mm to 78mm 80 X 60 FT1555-8060UP FT1555-8060BP 1,736 * Shorter length capsules are recommended for elbow/angled fittings. (i.e. 45 - degree and 90 - degree fittings). 10 | © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. AQ445452814730en-000101...
  • Page 11: Ce Declaration Of Conformity For Machineru

    Model: UC-CSS-230, production year 2010 is in conformity with the requirements of the Machinery Directive 73/23/EEC, 89/336/EEC Bridgeton, NJ 08302 USA, October 2010 Mark of Conformity Bruce Riley, Owner AQ445452814730en-000101 © Danfoss FT1555-BM bench mount capping machine Operator’s Manual | 2023.03. | 11...
  • Page 12: Contact Information

    Phone: +86 21 3418 5200w Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.